7c.)

PINK NOISE

is a built in pink noise generator

to test operation of the amplifier

Use the

UP

and

DOWN

keys to select

NOISE ON

or

NOISE OFf

.

When the PINK NOISE is ON

the

LEFT

and

RIGHT

indicators

in the

ISIS VFD will blink on

and off.

When you are done using the

PINK NOISE generator press the

ESC

key to return to the SICK

BAY menu.

NOTE...

If you exit the SICK BAY menu with the PINK NOISE generator

still on, the

LEFT

and

RIGHT

ISIS VFD indicators will remain

blinking as a reminder.

HOME

ENT

ESC

SYS

MEM-1

GAIN EQ LPF HPF

KOMP

AMP1

LOCK

MEM-2

MEM-3

MEM-4

PHASE

MUTE

AMP2

LEFT

RIGHT

noise on

HOME

ENT

ESC

8.)

Amp Name

- Here you can assign a unique name to

your KICKER SX amplifier. This name will replace the model
name in the DEFAULT screen. If you change your mind and
do not want to change the name, press and hold the

HOME

key for 1.5 seconds BEFORE making any changes.

The

ESC

and

ENT

keys move

the cursor left or right to select
which character to change.

Use the

UP

and

DOWN

keys to

change the character displayed

(A, B, C...1, 2, 3...etc)

When you are finished press and

hold the

HOME

key for 1.5

seconds to save your new
amplifier name.

HOME

ENT

ESC

HOME

ENT

ESC

HOME

ENT

ESC

PRESS &

HOLD

16

SX .4 Series Amplifiers

Opera

tion

SYSTEM

MENU - This menu item contains many diagnostic

tools and first time setup options. Use the

UP

and

DOWN

arrow keys to scroll through the options and press

ENT

to

select. Press the

ESC

key to return to the SYSTEM menu.

1.)

Volt Now

- Displays the current voltage at the

amplifiers +12 volt terminal.

2.)

Volt Min

- Displays the lowest voltage seen at the

amplifiers +12 volt terminal since being installed.

3.)

Volt Max

- Displays the highest voltage at the

amplifiers +12 volt terminal since being installed.

4.)

Temp Now

- Displays the current temperature of

the amplifier.

5.)

Temp Max

- Displays the highest temperature the

amplifier has reached since being installed.

6.)

Run Time

- Displays the total time the amplifier

has been powered up since installation in 1/10th of
an hour increments

7.)

Sick Bay

- Contains several

diagnostic tools. Once in this menu
you use the

UP

and

DOWN

keys to

scroll through

CURRENT

,

HISTORY

and

PINK NOISE

options. Press the

ENT

key to select.

7a.)

CURRENT

shows amplifiers current status or fault

code. The 6 possible codes are:

normal

- No problem, normal operation.

thermal

- Thermal cutoff protection engaged.

short

- Short circuit protection engaged.

Hi-Volt

- High voltage protection engaged.

FUSE

- Faulty or blown power fuse.

SERVICE

- Amp requires service by KICKER.

When you are done viewing

the current status press the

ESC

key to return to the SICK

BAY menu.

7b. )

HISTORY

logs the last 5 fault codes and how

long ago they happened when
compared to the RUN TIME log.

Use the

UP

and

DOWN

keys to select the

HISTORY

log

entry you want to view.

Press and hold the

ENT

key

to view the time it happened.

When you are done viewing

the history press the

ESC

key.

HOME

ENT

ESC

HOME

ENT

ESC

HOME

ENT

ESC

HOME

ENT

ESC

HOME

ENT

ESC

Advertising