Model Revision 1

• Available downstream modules:
- DQM 16: 16 channels, 4 chan. per port
- DS-IO 04: Interface card for

downstream module

Note: For each DQM 16 one DS-IO 04 is
required.

• Available upstream modules:
- DCU 16: 16 channels, 1 chan. per port
- DCU 32: 32 channels, 2 chan. per port
- US-IO 16: Interface card for

upstream

modules

Note: For each DCU 16/32 one US-IO 16 is
required.

• Available module for redundancy
operation
- RF-RD: Module for n+1 redundancy in
down and upstream, 1+1 redundancy
of Switch and Management Module
including RF switch and redundancy
software
Note: If the RF-RD module is operated,
then a DQM 16 or resp. a DCU 16/32
or resp. SMM-12GE should be foreseen
as a redundancy module for each unit.

Note: The required system down and
upstream configuration can be factory
installed and delivered pre-configured.
Modules can also be ordered individu-
ally and hot plug and play installed or
exchanged during operation.

• High operational availability with hot
plug-and-play exchangeable modules

• Switch and Management Module
- Switch capacity: 48 x 2 Gbps
- 12 Ethernet SFP ports
10/100/1000 Mbps
- 1+1 redundancy possible using a
second module

Note: The number of required SFP modules
is determined by the desired data rate and
redundancy requirements

Model Revision 2

• Available downstream modules:
- DQM 32: 32 channels, 4 chan. per port
- DQM 64: 64 channels, 8 chan. per port
- DS-IO08: Interface card for

downstream modules

Note: For each DQM 32/64 one DS-IO08
is

required.

• Available upstream modules:
- DCU 32: 32 channels, 2 chan. per port
- DCU 64: 64 channels, 4 chan. per port
- US-IO16: Interface card for upstream
modules

For each DCU 32/64 one US-IO16 is

required.

• Available module for redundancy operation
- RF-RD: Module for n+1 redundancy in
down and upstream, 1+1 redundancy of
Switch and Management module including
RF switch and redundancy software

Note: If the RF-RD module is operated,
then a DQM 32/64 or resp. a DCU 32/64 or
resp. SMM-10xGE should be foreseen as a
redundancy module for each unit.

Note: The required system down and
upstream configuration can be factory
installed and delivered pre-configured.
Modules can also be ordered individu-
ally and hot plug and play installed or
exchanged during operation.

• High operational availability with hot
plug-and-play exchangeable modules

• Switch and Management Module
- Switch capacity: 24 x 20 Gbps
- 2 Ethernet 10 GbE SFP+ Ports
- 8 Ethernet SFP ports 10/100/1000 Mbps
- 1+1 redundancy possible using a second
module

Note: The number of required SFP modules
is determined by the desired data rate and
redundancy requirements

Advertising