Echolink- setting up echolink sysop mode – Kenwood RC-D710 User Manual

Page 24

Advertising
background image

EchoLink-

sETTing Up EchoLink sysop MoDE

Connect the TM-V71 to a personal computer to use the

system as a node station for EchoLink relaying.
When connecting to a personal computer and using the

EchoLink Sysop mode, the hard flow control operation

RTS and CTS computer terminals operate the same as

and are changed with the SQC (squelch control signal

output to the computer) and PKS (transmit control signal

input from the computer) data terminals.
The current band becomes the same as the data band

which is selected in menu No. 517, regardless of the

transmission band and operation band.
Use the PG-5H (interface cable kit) when connecting to a

personal computer.

1 Turn the transceiver power OFF.
2 Press [PF2] + Power ON to turn EchoLink Sysop

Mode ON.

• The icon appears on the display when EchoLink Sysop

mode is ON.

• When the audio signal is output to the PC side, the icon

blinks.

• To turn EchoLink Sysop Mode OFF, press

[PF2] + Power

ON again.

EchoLink Sysop Mode ON

EchoLink Sysop Mode OFF

PC

terminal

PC

PC

terminal

PC

TxD

–>

RxD

TxD

–>

RxD

RxD

<–

TxD

RxD

<–

TxD

SQC

–>

CTS

RTS

–>

CTS

PKS

<–

RTS

CTS

<–

RTS

GND

<–>

GND

GND

<–>

GND

Note:
u

When using EchoLink Sysop mode, perform the following settings

(1) ~ (4).
(1) Set the SQC output setting (Menu No. 520) to “SQL”.
(2) When unnecessary noise signals, etc., are sent from the link

station to the internet while CTCSS and DCS are active, use

can verify the usage condition of the operating frequency by

setting “EchoLink RX Monitor” ([Edit] > [Menu] > [Transmit/

Receive]) via the MCP-2A to “Busy Only”.

Because of this, when EchoLink Sysop mode is ON, all

received signals on the DATA band are output from the

speaker irregardless of a matching CTCSS or DCS signal.

(Voice signals are output from the DATA terminal only when

the CTCSS or DCS signals match.)

(3) To avoid having the EchoLink software detecting a busy state

even when the transceiver power is turned OFF, set the “SQC

Output Logic” ([Edit] > [Data Terminal]) via the MCP-2A to

“High”.

(When performing this setting, ensure that the EchoLink’s

software “Invert Sense” setting in the RX Ctrl tab of the Sysop

Setup window is not checked.)

(4) When the audio level adjustment range on your personal

computer is insufficient, adjust the AF output level “PR1

Pin Output Level” ([Edit] > [Data Terminal]) and AF input

sensitivity “PKD Pin Input Level” ([Edit] > [Data Terminal]) of

the transceiver via the MCP-2A. Adjustments can be made in

steps of 6dB.

u

The settings in numbers 2 ~ 4 (above) can be performed only

using a MCP-2A.

u

In the older version of the MCP-2A, there are times when the

menu position is not different. Use MCP-2A version 3.0 and later.

u

When EchoLink Sysop mode is ON, it cannot communicate with

the MCP-2A. When using the MCP-2A, be sure to turn EchoLink

Sysop mode OFF.

Data communications cable

Serial communications cable

To PC audio terminal

Pink: To microphone input terminal

Green: To line out terminal

To PC 9-pin D-SUB

terminal

Advertising