Step One: Adjust and mount new valve

First, make sure that the valve is open. Try to turn the pet-cock on the valve counter-
clockwise. If you cannot turn it further counter-clockwise, it is open.

open valve counter-clockwise

The new valve allows you to rotate its housing for easy mounting.
Use the ½ inch open-ended wrench to loosen the nut on the top of the new valve. Loosen
it just enough that you can rotate the red metal housing of the valve.

turn nut counter-clockwise

By adjusting the housing, you can mount the valve so that each hose easily reaches it,
while the electrical wires are leaving the valve in the direction of the hole in the computer
control system box. When you have adjusted the housing, tighten the nut on top of the
valve, so that the housing does not move.

position housing on valve