Lennox Hearth Direct Vent MPD-40 Series User Manual

Page 4

Advertising
background image

4

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Shelf Above Fireplace With Rear Venting

Do not insulate the

space between the

appliance and the

area above it.

Shelf Height

(

see table)

Shelf Height

(

see table)

Do not insulate the

space between the

appliance and the

area above it.

Shelf Above Fireplace With Top Venting

.

o

N

l

e

d

o

M

)

m

m

(

s

e

h

c

n

i

t

h

g

i

e

H

f

l

e

h

S

w

o

b

l

E

e

e

r

g

e

D

0

9

e

n

O

h

t

i

w

-

t

n

e

V

p

o

T

k

c

a

B

e

h

t

t

u

O

t

h

g

i

a

r

t

S

-

t

n

e

V

r

a

e

R

t

n

e

V

e

r

u

c

e

S

x

e

l

F

e

r

u

c

e

S

t

n

e

V

e

r

u

c

e

S

x

e

l

F

e

r

u

c

e

S

8

2

3

3

-

T

D

P

M

2

/

1

4

4

)

0

3

1

1

(

4

/

1

6

4

)

5

7

1

1

(

A

/

N

A

/

N

8

2

3

3

-

R

D

P

M

A

/

N

A

/

N

4

/

1

3

3

)

5

4

8

(

4

/

1

3

3

)

5

4

8

(

0

3

5

3

-

D

P

M

2

/

1

6

4

)

1

8

1

1

(

4

/

1

8

4

)

6

2

2

1

(

3

4

/

1

5

)

5

9

8

(

3

4

/

1

5

)

5

9

8

(

5

3

0

4

-

D

P

M

0

4

5

4

-

D

P

M

2

/

1

1

5

)

8

0

3

1

(

4

/

1

3

5

)

3

5

3

1

(

4

/

1

0

4

)

2

2

0

1

(

4

/

1

0

4

)

2

2

0

1

(

K

C

A

B

)

m

m

3

1

(

.

n

i

2

/

1

s

r

e

c

a

p

s

)

m

m

0

(

.

n

i

0

S

E

D

I

S

*

*

)

m

m

3

1

(

.

n

i

2

/

1

s

r

e

c

a

p

s

)

m

m

0

(

.

n

i

0

S

R

E

C

A

P

S

P

O

T

)

m

m

0

(

.

n

i

0

R

O

O

L

F

)

m

m

0

(

.

n

i

0

m

o

t

t

o

B

m

o

r

F

o

t

t

i

n

U

f

o

g

n

il

i

e

C

)

m

m

6

2

6

1

(

.

n

i

4

6

T

N

E

V

*

)

m

m

4

.

5

2

(

.

n

i

1

S

E

C

N

A

R

A

E

L

C

E

C

I

V

R

E

S

T

N

O

R

F

)

s

r

e

t

e

m

9

.

0

(

.

t

e

e

F

3

(Rear Vent Application

HORIZONTAL VENT

without a chase)

HORIZONTAL VENT
(Rear Vent Application
With a chase)

HORIZONTAL VENT
(Top Vent
Application)

VERTICAL VENT
(Top Vent
Application)

(Rear Vent

VERTICAL VENT

Application)

APPLICA

TION

REAR VENT

APPLICA

TION

TOP VENT

APPLICATION

TOP VENT

REAR VENT

APPLICA

TION

TOP VENT

APPLICA

TION

RECESSED

INSTALLATION

TOP VENT

APPLICATION

APPLICA

TION

TOP VENT

APPLICA

TION

TOP VENT

Figure 2

Figure 3

*Note: 3 in. (75 mm) above any horizontal/
inclined vent component.

**Note: See page 5, step 1 for clearance
requirements to the nailing flange located
at each side of the unit and any screw
heads adjacent to it.

Table 2

APPLIANCE AND VENT CLEARANCES

The appliance is approved with zero clearance
to combustible materials on all sides (as de-
tailed in

Table 2 ), with the following exception:

When the unit is installed with one side flush
with a wall, the wall on the other side of the unit
must not extend beyond the front edge of the
unit. In addition, when the unit is recessed, the
side walls surrounding the unit must not extend
beyond the front edge of the unit. See

Figure 2.

Typical Locations

The appliance should be mounted on a fully
supported base extending the full width and
depth of the unit. The appliance may be located
on or near conventional construction materi-
als. However, if installed on combustible mate-
rials, such as carpeting, vinyl tile, etc., a metal
or wood barrier covering the entire bottom
surface must be used.

LOCATION

In selecting the location, the aesthetic and
functional use of the appliance are primary
concerns. However, vent system routing to the
exterior and access to the fuel supply are also
important. Due to high temperatures the
appliance should be located out of traffic
and away from furniture and draperies.
Consideration should be given to traffic ways,
furniture, draperies, etc., due to elevated sur-
face temperatures (

Figure 2 ). The location

should also be free of electrical, plumbing or
other heating/air conditioning ducting.

These direct vent appliances are uniquely suited
for installations requiring a utility shelf posi-
tioned directly above the fireplace. Utility shelves
like these are commonly used for locating tele-
vision sets and decorative plants.

To provide for the lowest possible shelf surface
use the alternate rear vent outlet with attached
venting routed in a way to minimize obstruc-
tions to the use of the space above the appli-
ance. Do not insulate the space between the
appliance and the area above it. See

Figure 3.

The minimum height from the base of the appli-
ance to the underside of combustible materials
used to construct a utility shelf in this fashion is
shown in the table in

Figure 3.

Advertising
This manual is related to the following products: