20 operating your appliance, Troubleshooting problem possible cause – Lopi Revere User Manual

Page 20

Advertising
background image

20

Operating Your Appliance

© Travis Industries

100-01165

4040806

Troubleshooting

Problem

Possible Cause

Smoke Enters Room During
Start-Up

•

Open the bypass (pg. 15).

•

Open the air control (pg. 17).

•

Cold Air Blockage - burn a piece of newspaper to
establish a draft.

•

If the flame is not getting enough air, a small crack in
the door is all that is needed.

Kindling Does Not Start - Fire
Smolders

•

Open the bypass (pg. 15).

•

Open the air control (pg. 17).

•

Not enough starter paper - use additional newspaper if
necessary.

•

If the flame is not getting enough air, a small crack in
the door is all that is needed.

Smoke Enters Room While Re-
Loading

•

Open the bypass before opening the door (pg. 15).

•

Open the air control before opening the door (pg. 17).

•

Let the air stabilize before fully opening the door. Then
open the door approximately 1 inch. Let air go into the
firebox for a few seconds. Once the smoke appears to
be flowing up the chimney consistently, open the door.

•

Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases a
small amount of smoke may enter the home. Adding
more pipe or a draft-inducing cap may help.

Stove Does Not Burn Hot Enough

•

Wood is Wet - see the section "Selecting Wood" on
page 19 for details on wood.

•

Make sure the air control is all the way open. Slide the
control back and forth to insure the control is not stuck.

•

Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases
the fire may burn slowly. Adding more pipe or a draft-
inducing cap may help.

Blower Does Not Run

•

Stove is Not Up to Temperature - This is normal. The
blower will come on when the stove is hot - usually 15
to 30 minutes.

•

Electricity is Cut to the Blower - Check the household
breaker or fuse to make sure it is operable.

Stove Does Not Burn Long
Enough

•

Depending upon wood, draft, and other factors, the
burn time may be shorter then stated. Make sure the
doors are sealing and not allowing air into the firebox -
See the section "Door and Glass Inspection" on page
22 for details.

•

Check the ash bed for coals. Often, coals are still
glowing under a slight bed of flyash. By raking these
into a pile you can re-start your stove quickly.

Advertising