28 listing label – Lopi Revere User Manual

Page 28

Advertising
background image

28

Listing Label

© Travis Industries

100-01165

4040806

Listing Label

CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND

INSTALLATION INSPECTION IN YOUR AREA

MODEL:

LOPI

®

REVERE

(X-NT)

Report No. 028-S-44-4

SERIAL NO:

Listed Fireplace Insert for installation into a Factory-Built (Z.C.) fireplace or masonry fireplace
WARNING - DO NOT REMOVE THIS LABEL

A representative product sample of this model stove has been tested to meet UL 1482
Standards for safety. For use with solid wood fuels only. Install and use only in accordance
with the manufacturers installation and operation instructions. Check all local building
codes. DO NOT ELEVATE FIRE. Build fires directly on the firebrick. Install with or without a
direct flue connector pipe in a MASONRY FIREPLACE with facing shroud plates.

Factory-Built (Z.C.) Fireplace installations require a minimum 24” starter section directly
connected to the fireplace chimney or a full re-line. Factory-Built (Z.C.) Fireplace chimney
must have a minimum cross-sectional area of 28.85”. The Factory-Built (Z.C.) Fireplace
damper and control must be removed, or secured in the open position. For minimum
Factory-Built (Z.C.) Fireplace firebox size, see manufacturer’s installation instructions.
Factory-Built (Z.C.) Fireplace floor protection must be 3/8” minimum non-combustible
material or equivalent, extending 16” in front of insert and 8” to both sides. A metal
deflector plate must be installed if the flue collar is not completely behind the Lintel plate
of the Factory-Built (Z.C.) Fireplace openings.

Inspect and clean chimney frequently. Under certain conditions of use, creosote buildup
may occur rapidly. DO NOT OVERFIRE. If heater glows, you are overfiring. Do not remove
bricks or mortar from masonry fireplace. OPEN DAMPER BEFORE OPENING LOADING
DOORS! Maintain 36" front clearance to all furnishings and other combustible materials.

CLEARANCE TO COMBUSTIBLES, MASONRY FIREPLACE INSTALLATION

Minimum Clearance to

Masonry

Factory-Built

Combustibles and Hearth

Fireplace

(Z.C.) Fireplace

Requirements

Installations

Installations

A.

15”

30”

B.

13”

12”

C.

28.5”

12”

With Shield

20.5”

N/A

D.

30.5”

24”

With Shield

22.5”

N/A

Hearth Extension Front

16”

16”

Hearth Extension Sides

8”

8”

Electrical Rating:
Volts-115 Watts-21.4 Amps-1.8 HZ-60

Note: Replace glass only with 5mm Lopi

ceramic

OPTIONAL 125 CFM BLOWER PACKAGE

MANTEL

HEARTH

EXTENSION

F

ACIA

OR TRIM

INSERT

SIDEW

ALL

INSERT CLEARANCE DIAGRAM

A

B

C

D

8

16

10850 117th Pl. N.E. Kirkland, WA 98033

Manufactured By:

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with July 1990 particulate emission standards.

Date of Manufacture

2001 2002 2003 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.

0234