Lennox Hearth COUNTRY COLLECTION 506033-35 User Manual

Page 2

Advertising
background image

2

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 2

Stove Back

Blower

INSTALLATION INSTRUCTIONS

Removing Existing Blower From Stove

Step . UNpLUG pOWER CORD AND ENSURE AppLIANCE IS COLD

Step 2. Using a 5/32 allen wrench/T-handle, remove the blower mounting

allen screws from blower, and remove blower from stove. See

Figure 2.

Figure 3

Step 3. Using a crescent wrench, remove the fan blade. NOTE: Fan nut is

reverse thread.

Step 4. Using a 3/8” end wrench, remove the ground (green) wire from the

blower stud. See Figure 3.

Green Ground Wire

Step 5. Carefully remove the black heat shrink sleeve material from

blower wires.

Step 6. Cut both butt connectors on the motor side. Note: Cut at the

connector being careful to not remove any more wire than is

necessary. See Figures 4 and 5.

Figure 4

Figure 5

Step 7. Strip blower wires and connect butt connectors to both. See

Figures 6 and 7.

Figure 6

Cut black wires on motor

side of butt connectors

Butt Connectors

Cut Wires Shown

Strip wires as shown

Advertising