Lennox Hearth CATALYTIC VENT-FREE X-FIRES-WS-NG User Manual

Page 10

Advertising
background image

10

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Non-concealed gas connections may be made

using the entry points on the base of the firebox .

A concealed gas connection may be made using

the knockout hole in the center back of the firebox .

Select the most appropriate entry point and knock

out the relevant hole .

No more than 59" of 1/4" diameter pipe must be used

to avoid unnecessary pressure drops .

If a concealed gas con nection is to be made, the

supply pipe should always be sleeved through walls

and floors using the shortest possi ble route .

For concealed supply pipe routing, pipes must

(where possible) be ver tical and providing there is

sufficient wall thick ness available, they should be

placed in pipe chases . Horizontal pipe runs should

be avoided where possible . Prior to chasing a

solid wall, an inspection should be made to note

the proximity of any cables/sockets outlets which

may already be buried . Pipes must be secured using

suitable clips and protected against corrosion .

Ideally factory finished protected pipe-work and

fittings should be used . Joints should be kept to

a minimum and compression fittings must not be

used . The pipe-work installation must be tested for

soundness before any protection is applied and/or

the pipe-work and fittings are buried .

Remove the wall mounting plate from the back of the appliance firebox by removing the two

retaining wing nuts (indicated by arrows in Figure 2) from the retaining studs that protrude

into the lower part of the main firebox .

PREPARING THE APPLIANCE

Figure 2

Wall Mounting Plate

Firebox

GAS SUPPLY ROUTES

IMPORTANT NOTE: All gas piping must be done by

a licensed plumber or gas fitter and must conform

to the requirements of the National Fuel Gas Code

NFPA 54 / ANSI Z223.1 - latest edition.

Gas connection: The heater gas inlet connection is

3/8” NPT at the regulator, located below the burner,

in the right hand side of the heater . There are four

possible entry points for the gas supply pipe-work

to enter the appliance firebox . These entry points are

‘knock out’ type holes (shown in Figure 1) .

Figure 1 - Gas Supply Entry Points

NOTE: See Page 22 for gas line entry

point dimensions.

Advertising
This manual is related to the following products: