Warning – Lennox Hearth CATALYTIC VENT-FREE X-FIRES-WS-NG User Manual

Page 14

Advertising
background image

14

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

SPARK GAP

Figure 8 - Proper Spark Gap

1/8" to 3/16" Spark Gap

BRIEFING THE CUSTOMER

WARNING

Do not add logs or ornaments such as pine cones,

vermiculite or rock wool. Using these added items

can cause sooting.

All instructions must be left in the possession of the user for safekeeping .

If at all possible, show the customer how to light and control the appli-

ance and show the customer how to remove and replace the surround

assembly and glass door assembly .

After commissioning the appliance, the customer should be instructed

on the safe use of the appliance and the need for regular servicing .

Frequency of service depends on usage, but MUST be carried out

at least once annually . Advise that cleaning of the appliance may be

achieved when the fire is cold using a damp cloth and mild detergent

on most surfaces .

Advise that the fireplace will emit a "newness" smell for a time after

initial commissioning and that extra ventilation may be needed during

this time . Recommend that a guard be used for the protection of the

young, pets, the elderly and the infirm .

Advise the user to never place any objects on top of the appliance or

obstruction this area in any way.

A periodic visual check of the pilot flame and the burner flame should

be carried out .

The gap between the spark electrode and the pilot should be 1/8” to

3/16” to produce a good spark . There should be no need to adjust this

(DO NOT ATTEMPT TO ADJUST THE GAP) . If under any circumstances

the piezo electric spark fails, the pilot cannot be lit manually .

Adjustment to the

pilot is Not allowed

17.0 GAS PRESSURE CHECK

Figure 7a - Remove test point screw

Figure 7b - Check regulator pressure

The heater regulator controls the burner pressure which should be

checked at the pressure test point located on the appliance inlet pipe .

The appliance inlet pipe runs between the regulator and the gas valve

and the test point is located next to the regulator as shown in Figure 7a .

The test point is situated before the appliance gas valve so it will be

necessary to turn off the gas supply before removing the test point

screw . Connect the pressure gauge .

Turn on the gas supply and light the heater . Turn the control to the high

flame setting and check the pressure . The pressure regulator on manual

models is preset and locked to avoid tampering . If the pressure is not as

specified in Table 1 on Page 7, replace the regulator with P/N H6063

for Natural Gas units and H7001 for Propane Gas units . Replace the test

point screw ensuring no gas leaks .

WARNING

Turn off the gas supply before removing the pressure

test point screw.