Operation, Front panel controls – Lincoln Electric MULTI-WELD SVM151-A User Manual

Page 18

Advertising
background image

FRONT PANEL CONTROLS

The numbered items of Figure B.2 match the num-
bered items described below:

These few instruments and controls are basic to the
operation and monitoring of the Converter. They are
intuitively laid out so that the panel left side is weld cur-
rent related, and the right side is weld voltage related:

(1) Input Power/ Mode Switch has three positions:

Center is OFF, which shuts off input power to the
Converter.

• Neither displays nor output is on if in OFF

position.

Left is on for CC (constant current) welding mode.

• Only AMPS digital meter is lit, displaying the

preset current setting.

• Output will be on at o.c.v. (open circuit voltage).

Right is on for CV (constant voltage) welding
mode.

• Only VOLTS digital meter is lit, displaying the

preset voltage setting.

• Output will be on at the output voltage setting.

(2) Output Control has 3-3/4 turn resolution with slip-

clutch to prevent control pot damage.

In CC mode it presets AMPS (30-350A range)
when not welding and adjusts actual arc current
while welding.

In CV mode it presets VOLTS (15-40v range)
when not welding and adjusts actual arc voltage
while welding.

(3) AMPS Digital Meter is a 3-1/2 digit LED meter

which displays:

Preset AMPS in CC mode when not welding.

“Blank” in CV mode when not welding.

Actual AMPS while welding in both CC and CV
modes.

B-6

B-6

OPERATION

MULTI-WELD 350

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

1

2

3

4

5

6

7

8

9

10

INPUT

WORK

ELECTRODE

+

+

FIGURE B.2 – FRONT PANEL CONTROLS