Hardwired keypad features – Linear DUAL 824 User Manual

Page 8

Advertising
background image

6

1 BEAUTY

COVER

★ The beauty cover snaps open and shut to hide the keypad’s keys, mode and

supervisory indicators, and the sensor location labeling area.

2 KEYPAD

★ Backlit keys for easy viewing in low light conditions.

★ For entering the user's user code (numerically or alphabetically).

★ Used when programming system options.

★ Press to activate the Automation Output.

★ Press to clear keypad if the wrong key is pressed.

★ Press for two seconds to view sensor battery and supervisory status (see

BATTERIES and RADIO indicator description).

3 24-HOUR

BUTTONS

★ Pressing FIRE for two seconds sounds the fi re siren and sends a “fi re” message

to a central monitoring station through the digital communicator (if the system
is monitored).

★ Pressing EMERGENCY for two seconds sounds the emergency siren and sends

an “emergency” message to a central monitoring station through the digital
communicator (if the system is monitored).

★ Both work even when system is disarmed.

★ IMPORTANT: For personal emergency use only. Not for use as a UL Listed

Medical Alert System.

4

SYSTEM SUPERVISORY INDICATORS

★ Shows the current status of the system.

POWER LIGHT

★ Glows when AC power is on.

★ Blinks when AC power is off and backup battery is installed.

★ Blinks when the backup battery is low, recharging or missing.

★ Off when AC power is off and no backup battery is installed (system disabled).

BATTERIES LIGHT

★ Blinks when one or more sensors have a low battery.

★ Press for two seconds to view sensor status. Sensor status indicator for any

sensor with a low battery will light along with the BATTERIES indicator.

★ Switch to Test Mode after replacing the sensor battery and completely test the

system (see Test Mode). Switching to Test Mode clears the low battery indication.

RADIO LIGHT

★ Blinks when one or more sensors have not reported status during the eight hour

status time period.

★ Press for two seconds to view sensor status. Sensor status indicator for any

sensor that has not reported in will light along with the TROUBLE indicator.

★ Switch to Test Mode after servicing the sensor and completely test the system

(see Test Mode). Switching to Test Mode clears the trouble indication.

5 MODE

INDICATORS

★ The indicators next to the mode keys light to show the current system mode.

★ HOME indicator will blink during Secure Exit and Home Instant modes.

★ AWAY indicator will blink during the exit delay in the Away Mode.

6 MICROPHONE

(OPTIONAL)

★ Location for the high sensitivity microphone included with the Model RSM-2

speaker/microphone kit.

★ Detects room audio when communicator is reporting to the Central Station

in 2-way audio mode (Model VB-2 digital voice response module and RSM-2
speaker/microphone kit must be installed).

7

SENSOR STATUS INDICATORS

★ Blacked-out sensor status indicators are only visible when lit.

★ Indicate the status of each of the system's wireless sensors and hardwired

loops.

★ Indicators show which doors and windows are open.

★ Indicators fl ash to display sensors that have caused an alarm.

★ Stick-on labels are provided to identify the custom sensor locations.

8

SYSTEM STATUS INDICATORS

★ Shows the current status of the system.

READY LIGHT

★ Lights when all system sensors are closed.

★ Shows that the system is ready to be armed.

★ The system can be armed without the READY indicator being lit, if sensors are

bypassed either manually or automatically.

ARMED LIGHT

★ Blinks during the exit delay.

★ Lights when the system is fully armed.

TROUBLE LIGHT

★ Lights when the system has detected supervisory trouble.

★ Supervisory trouble can be caused by power, sensor low battery, or sensor radio

supervision conditions.

★ Press for one second then view the system supervisory and status indicators

to determine the origin of the trouble.

9 MODE

BUTTONS

★ Used to operate the system.

OFF

★ Off Mode disarms the system.

★ Switching to Off Mode stops the alarm siren.

✓ Multiple Beeps sound and sensor status indicators fl ash if an alarm has

occurred.

☞ Multiple Beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.

CHIME

★ Chime Mode disarms the system.

★ Switching to Chime Mode stops the alarm siren.

✓ Multiple Beeps sound and sensor status indicators fl ash if an alarm has

occurred.

☞ Multiple Beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.

★ Chime Mode is for monitoring doors and windows.

✓ Use this mode as an “automatic door chime” when at home.

✓ Opening any protected door or window causes the keypad(s) to “ding-dong”.

HOME

★ Home Mode arms the perimeter sensors, but not the interior sensors.

✓ Use this mode when anyone is staying behind.

✓ Interior motion detectors and interior door sensors are not armed.

✓ Home secure mode makes all delayed perimeter sensors instant.

✓ Secure exit mode starts an exit delay while remaining in Home Mode.

✓ Re-entering during the exit delay restarts the exit delay (one time only).

AWAY

★ Away Mode arms the entire system.

✓ Use this mode when leaving home.

✓ Door sensors set for delayed will have a time delay that allows the user to

leave and enter the premises without sounding the alarm.

✓ Re-entering during the exit delay restarts the exit delay (one time only).

✓ Entry Delay Beeps warn the user to disarm the system before the siren

starts.

TEST

★ Test Mode is for testing the system sensors.

✓ All sensor status lights blink when the Test Mode is entered.

✓ Each sensor status light will stop blinking when its sensor is tested.

★ Hold the TEST button down to test all of the keypad's indicator lights.

10 SOUNDER

★ Makes unique sounds for burglary, fi re and emergencies.

★ Alarm sirens stop automatically after fi ve minutes.

★ Sounds advisory tones to confi rm keystrokes from the keypad.

★ Sounds mode selection tones.

★ Sounds alarm memory tones.

★ Beeps when Automation Output is activated.

★ The Control Panel has terminals available for an external siren.

11 SPEAKER

(OPTIONAL)

★ Location for the speaker included with the Model RSM-2 speaker/microphone

kit.

★ Sounds voice operating prompts and audio from the Central Station (Model

VB-2 digital voice response module and Model RSM-2 required).

4.

HARDWIRED KEYPAD FEATURES

4

3

5

9

6

7

8

10

1

2

11

Advertising