carbon Monoxide poisoning: early signs

of carbon monoxide poisoning are similar

to the flu with headaches, dizziness and/or

nausea. if you have these signs, obtain

fresh air immediately. turn off the gas sup-

ply to the appliance and have it serviced by

a qualified professional, as it may not be

operating correctly.

Figure 1

WarninG: FaiLure to coMpLy WitH

tHe instaLLation and operatinG

instructions proVided in tHis

docuMent WiLL resuLt in an iM-

properLy instaLLed and operatinG

appLiance, VoidinG its Warranty.

any cHanGe to tHis appLiance

and/or its operatinG controLs

is danGerous. iMproper instaL-

Lation or use oF tHis appLiance

can cause serious injury or deatH

FroM Fire, Burns, expLosion or

carBon Monoxide poisoninG.

WarninG: cHiLdren and aduLts

sHouLd Be aLerted to tHe Hazards

oF HiGH surFace teMperatures.

use caution around tHe appLi-

ance to aVoid Burns or cLotHinG

iGnition. younG cHiLdren sHouLd

Be careFuLLy superVised WHen

tHey are in tHe saMe rooM as tHe

appLiance.

aVertisseMent: surVeiLLer Les

enFants. Garder Les VêteMents,

Les MeuBLes, L'essence ou autres

LiQuides à Vapeur inFLaMMaBLes

Loin de L'appareiL.

Any safety guard or screen removed for ser-

vicing the appliance must be replaced prior to

operating the appliance.

Table 1

Tables 1 shows the units' gas orifice size for

the elevations indicated.

The appliance and its individual shut-off valve

must be disconnected from the gas supply

piping system during any pressure testing of

that system at pressures in excess of 1/2 psig

(3.5 kPa).

The appliance must be isolated from the gas supply

piping system (by closing its individual manual

shut-off valve) during any pressure testing of the

gas supply piping system at test pressures equal

to or less than 1/2 psig (3.5 kPa).

WarninG: do not pLace cLotHinG

or otHer FLaMMaBLe MateriaLs

on or near tHis appLiance.

units are tested and approved for elevations

of 0 to 4500 feet (0 to 372 meters).

For elevations above 4500 feet (372 meters),

install the unit according to the regulations of

the local authorities having jurisdiction and,

in the usa, the latest edition of the national

Fuel Gas code (ansi z223.) or, in canada,

the latest edition of the can-B49. and

.2 codes.

Maximum manifold pressure is 3.5 in. w.c. (0.87

kPa) for natural gas and 10 in. w.c. (2.49 kPa)

for LP/Propane gas.

The minimum manifold pressure on low is 2.2

in. w.c. (0.55 kPa) for natural gas and 6.3 in.

w.c. (1.57 kPa) for LP/Propane gas.

Do not use these appliances if any part has

been under water. Immediately call a qualified,

professional service technician to inspect the

appliance and to replace any parts of the control

system and any gas control which have been

under water.

Ne pas se servir de cet appareil s'il a été plongé

dans l'eau, complètement ou en partie. Appeler

un technicien qualifié pour inspecter l'appareil

et remplacer toute partie du système de con-

trôle et toute commande qui ont été plongés

dans l'leau.

Test gage connections are provided on the front

of the electronic gas control valve (identified OUT

for the manifold side and IN for inlet pressure.

A 1/8" NPT test gage connection is provided on

the electronic gas control valve adjacent to the

outlet to the main burner.

Minimum inlet gas pressure to these appli-

ances is 5.0 inches water column (1.24 kPa)

for natural gas and 11 inches water column

(2.74 kPa) for propane for the purpose of input

adjustment.

Maximum inlet gas supply pressure to these

appliances is 10.5 inches water column (2.61

kPa) for natural gas and 13.0 inches water

column (3.23 kPa) for propane.

Model

no.

orifice size

elevation

Feet

(meters)

natural

Gas

propane

e36odG

0.1405"

(#28)

0.0785"

(#47)

0-4500

(0-1372)

e42odG

0.1405"

(#28)

0.0785"

(#47)