Lincoln 1130-08H-A User Manual

Page 16

Advertising
background image

Impinger II – Advantage Digital Express Service Manual - Domestic

16

1130-080-A

120/208VAC

60

HZ.

1

PHASE

1130-080-A1

120/208VAC

60

HZ.

1

PHASE

1130-08H-A

208 VAC

60 HZ.

1 PHASE

1131-080-A

120/240VAC

60

HZ.

1

PHASE

1131-080-A1

120/240VAC

60

HZ.

1

PHASE

1131-08H-A

240 VAC

60 HZ.

1 PHASE

1132-080-A

120/208VAC

60

HZ.

3

PHASE

1132-080-A1

120/208VAC

60

HZ.

3

PHASE

1132-08H-A

208 VAC

60 HZ.

3 PHASE

1133-080-A

120/240VAC

60

HZ.

3

PHASE

1133-080-A1

120/240VAC

60

HZ.

3

PHASE

1133-08H-A

240 VAC

60 HZ.

3 PHASE

1161-080-A

120/240VAC

60

HZ.

1

PHASE

1162-080-A

120/208VAC

60

HZ.

3

PHASE

SYMPTOM POSSIBLE

CAUSE

EVALUATION

Oven fan will not run

Incoming power supply

Check circuit breakers. Reset if required. Call
power co. if needed.

Fuses, 10 Amp, motor and
controls

Check, replace if necessary.

Fuse holder

Check, replace if necessary.

Hi-limit thermostat,
Oven cavity

Terminals are normally closed. If open, reset
thermostat and retest. If thermostat will not hold
for maximum oven temperature, and oven is not
exceeding temperature setting, check for proper
location of capillary bulb in its spring holder. If the
capillary checks okay, replace the hi-limit
thermostat.

Switch, main power

Check continuity between switch terminals.
Replace switch as needed.

Relay, oven start

Check for 120VAC supplied to coil of relay. If no
voltage is present, trace wiring back to main
power switch. If voltage is present, check for pull
in of relay contacts. Replace relay as needed.

20 minute time delay

Check for 120VAC at terminal #1 to neutral on
time delay relay. If voltage is not present, trace
wiring back to 10A. fuse. If voltage is present at
terminal #1, check for 120VAC at terminal #2 to
neutral. If no voltage is present, and oven start
relay is closed, replace 20 minute time delay relay.

Relay, main fan

Check for 120VAC to coil of main fan relay. If no
voltage is present, trace wiring back to 20 minute
time delay relay. If voltage is present, check to
insure that relay contacts are closing. Replace
relay as needed.

Main fan motor

Check for supply voltage at motor. If no voltage is
present, trace wiring back to main fan relay.
WITH POWER OFF: Check for opens, shorts or
grounds. Turn fan blade to check for locked rotor.

Capacitor

Check for shorts or grounds.
WARNING: Capacitor has a stored charge,
discharge before testing.

No main fan cool down

20 Minute time delay

Check for 120VAC at terminal #2 to neutral while
the oven is ‘on’. Turn off the main fan switch,
120VAC should continue to be present for 20
minutes. If voltage is not present for approx. 20
minutes, replace the 20 minute time delay.

Oven fan relay

Check for 120VAC to relay coil, if no voltage is
present, trace wiring back to 20 minute time delay.
If voltage is present, be sure that relay contacts
stay closes during the 20 minute cool down.