Linak TECHLINE LA35 User Manual
Page 14
14
I/O Specifi cations: PLC-option
Item
Specifi cation
Comment
Description
Easy to use interface, with
integrated power electronics (Hbridge)
for direct PLC connection.
Soft start of the actuator.
See fi gure 5
Power supply
Input Voltage
12 V DC, +/- 20 %
24 V DC, +/- 10 %
Cable dimension 2 x 2,5 mm
2
(2 x AWG14)
Current consumption
12 V, 2-10 A depending on load
24 V, 1-5 A depending on load
Recommended fuse:
12V version = 20A fuse
24V version = 10A fuse
Inputs: Signals to the Actuator
Outwards direction
Extends the Actuator
FW – Red (Pin 2)
PNP
Inwards direction
Retracts the Actuator
BW – Black (Pin 1)
PNP
On/Off voltages
On voltage (High):
> 67 % of the power supply
Off voltage (Low):
< 33 % of the power supply
Examples on 24 V version:
On if the voltage is higher than 16 V
Off if the voltage is lower than 8 V
Input Impedance
10 K ohm
Input current
< 10 mA
Outputs: Signals from Actuator
Actuator fully
retracted (IN)
Signal when end stop switch in retracted
position is activated
IN = Yellow (Pin 5)
Max. 50 mA switching capacity
Actuator fully
extended (OUT)
Signal when end stop switch in extended
position is activated
OUT = Green (Pin 6)
Max. 50 mA switching capacity
Actuator ready
When the Actuator is ready the signal
is High
Ready = White (Pin 3)
Max. 10 mA switching capacity
Current cut-off 12 V version: 17 - 21 A
Current cut-off 24 V version: 8.5 - 10.5 A
Output voltage
Typical: Input voltage -1 V
Example on 24 V version:
Output voltage on IN = 23 V (+/-0.5V)
Output voltage on OUT = 23 V (+/-0.5V)
Output voltage on READY = 23 V (+/-0.5V)
Relative
positioning
For functional description see I/O
Specifi cations for Relative
positioning.
Max. 12mm switching capacity
35xxxxx2Hxxxxx
Absolute
positioning
For functional description see I/O
Specifi cations for Absolute
positioning.
35xxxxx2Axxxxx
Connection
See fi gure 5
Use cables 0367002-XXXX and 0367003-XXXX
35
2A
35
2H
See fi gur
g
g
e 5