ops Panel LEDs

other

associated LEDs or alarms

State Description

P

ower

o

n

(g

reen)

System Fault

(a

mber)

Logical Fault (a

mber)

3

Bo

x

identify

(Blue)

On

On

On

On

12big rack serial Module activity LEDs flash

Ops Panel power on test state.

On

Off

any

any

Power On. All functions good.

On

On

any

any

Dual Fan Cooling Module Fault LED on.
Continuous beep.

Dual Fan failure.

On

Flash

any

any

Dual Fan Cooling Module Fault LED on.
Intermittent beep.

Single Fan failure.

On

Flash

any

any

PSU Module Fault LED on.
Intermittent beep.

Single PSU failure.

On

Flash

any

any

Intermittent beep.

PSU removed.

On

Flash

any

any

Intermittent beep.

Over or under temperature warning.

On

On

any

any

Continuous beep.

Over or under temperature critical.

On

On

any

any

Continuous beep.

Voltage critical.

On

Off

As per Drive fault

LED

any

None

Drive critical.

On

Off

As per Drive fault

LED

any

None

Drive non-critical.

On

On

any

any

12big rack serial Fault & ID LEDs on.
Continuous beep.

12big rack serial Module watchdog failure.

On

Flash

any

any

2

12big rack serial Fault & ID LEDs on.
Internittent beep.

12big rack serial Module soft (or POST)
failure.

On

Flash

any

any

2

12big rack serial Fault & ID LEDs on.
Intermittent beep.

Other 12big rack serial Module fault.

LED operation set via SES Control page 0x02

On

any

Off

any

Power On. All functions good.

On

any

As per Drive fault

LED

any

Drive Bay Fault LED flash.

POST fault bit set for any Array Device
Element.

On

any

As per Drive fault

LED

any

Drive Bay Fault LED flash.

Other Array bits set for any Array Device
Element.

On

On

any

any

Continuous beep.

UNRECOV bit set in Audible Alarm element.

On

any

any

any

Intermittent beep.

INFO, NON-CRIT, CRIT bits set in Audible
Alarm element

On

any

any

any

Continuous beep.

UNRECOV bit set in Audible Alarm element.

On

Flash

any

any

REQUEST WARNING bit set in Enclosure
element.

On

On

any

any

REQUEST FAILURE bit set in Enclosure
element.

On

any

any

Flash

RQST IDENT bit set in Enclosure element.

notes

The 12big rack serial alarm pattern is a 1 second on, 1

1.

second off sequence, applied to all 12 Activity LEDs.

If an 12big rack serial fault LED is fitted, this will be set for

2.

all the above conditions. In addition this LED will flash for
an 12big rack serial module soft failure.

The Logical Fault LED will take the state of the highest

3.

priority drive bay fault LED.