Faults, causes and rectification – Lochinvar TISUN SPS0500 User Manual

Page 15

Advertising
background image

15

10

Faults, causes and

rectification

Pump doesn’t run when power is

switched on :

■ Check solar control unit for correct settings and tight wire
connections.

■ Check fuses.

■ Check pump voltage, refer to the pump rating plate for
requirements.

■ Close shut-off instruments upstream and downstream of
pump at high liquid temperatures and system pressures.
Allow pump to cool first.

■ Fully unscrew bleed screw and check ease of movement of
pump rotor by turning the slotted shaft end with a
screwdriver; use force to turn if necessary.

Motor blocked:

■ In the event of cavitation caused by insufficient inlet
pressure, increase primary system pressure within allowable
range.

■ Check speed setting.

Pump Noise:

If the fault cannot be rectified, please contact your nearest
Lochinvar/TiSUN customer service representative.

SL-PS Installation & Operation Manual