• RAID Level 0 – Striped disk array

– Two hard disk drives minimum

– Better performance without fault tolerance

• RAID Level 1 – Mirrored disk array

– Two hard disk drives minimum

– Improved read performance and 100% redundancy

• RAID Level 5 – Block-level striped disk array with distributed parity

– Three hard disk drives minimum

– Data striped at the byte level

– Stripe error correction information

– Better performance and fault tolerance

To install a new SAS hard disk drive, refer to the installation procedure in “Replacing a hard disk drive” in the
ThinkStation Hardware Installation and Replacement Guide.

Entering the Marvell BIOS Setup to configure SAS RAID

This section describes how to enter the Marvell BIOS Setup to configure SAS RAID.

1. Your computer must have a Marvell SAS adapter card (Marvell SAS controller) installed to configure

SAS RAID. For installing or replacing a Marvell SAS adapter card, refer to “Replacing an adapter card”
in the ThinkStation Hardware Installation and Replacement Guide.

2. Turn on the computer after you have installed the required number of SAS hard disk drives and the

Marvell SAS adapter card.

3. Press Ctrl+M when prompted to enter the Marvell BIOS Setup to configure SAS RAID.

Configuring the Marvell BIOS Setup to enable SAS RAID 0, 1, or 5
functionality

To enable SAS RAID 0, 1, or 5 functionality, use the Marvell BIOS Setup configuration utility as the SAS
configuration utility. This utility assumes that the system has the required number of hard disk drives.

1. Turn on your computer and press Ctrl+M when prompted to enter the Marvell BIOS Setup.

2. On the Marvell BIOS Setup screen, use the arrow keys to select RAID Config and press Enter. The

RAID Config menu opens.

3. From the RAID Config menu, select Create array.

4. Use the arrow keys and the Enter key to select each free hard disk drive that you want to include

in the array.

5. Select Next and press Enter.

6. From the Create array menu, select RAID level and press Enter.

Note: Only the valid RAID levels will be active.

7. Select the SAS RAID level you want (RAID 0, RAID 1, or RAID 5) and press Enter.

8. From the Stripe size menu, you can change the stripe size or keep it as default.

9. Type a proper array name in the Array name field.

10. Select Next and press Enter. When prompted, press Y to complete the array creation and RAID

configuration.