Installation, For qualified installers only), Travis industries – Lopi Leyden Pellet Stove User Manual

Page 15

Advertising
background image

Installation

(For Qualified Installers Only)

1 5

Travis Industries

4061016

1 0 0 - 0 1 1 8 4

Installation Example: Interior Vertical Installation

Floor Protection

24” Minimum

Insulation

must maintain

3” clearance.

Outside air may be drawn from
a ventilated crawl space.

2” Min.

3” Min.

Ceiling Support / Fire Stop Spacer

Roof Flashing

Storm Collar

Vertical Cap

Vent must

maintain 3”

clearance to

combustibles.

“L” Vent

Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections.

500

° F. RTV

Silicone

Floor Protection

7” Minimum

6” Minimum

3”

Minimum

2”

Minimum

“Tee”

Advertising