This insert may be installed in a masonry or factory built/zero

clearance (ZC) fireplace. When installing in a ZC fireplace,

the ZC grate must be removed and the ZC damper must be

removed or secured open. The ZC doors, screen, refractory

or masonry lining, baffles, and smoke shelf may be removed

if necessary to install the gas insert. However, do not cut or

alter the fireplace components. The removal of any parts to

facilitate installation must not alter the integrity of the inner or

outer shells of the fireplace cabinet. Any parts removed must

be replaceable if the insert is taken out of the fireplace or the

fireplace clearly marked with a paint stick that "This fireplace

has been altered and is no longer safe to operate."

The insert is designed to fit into a ZC fireplace with a mini-

mum firebox height of 19-1/2" (495mm). To facilitate this

the hood will need to be removed and discarded (Note: the

screws should be replaced in the insert body).

If the factory-built fireplace has no gas access hole(s) pro-

vided, an access hole of 1-1/2" (37.5 mm) or less may be

drilled through the lower sides or bottom of the firebox in

a proper workmanship like manner. This access hole must

be plugged with a non-combustible insulation after the gas

supply line has been installed.

The installer must mechanically attach the marking supplied

with the gas fireplace insert to the inside of the firebox of the

fireplace into which the gas fireplace insert is installed.

r

avenna

™ 40 C

onversion

t

o

r

avenna

33

To convert to a Ravenna 33 gas insert, after step 1 remove

and replace the stock burner orifice with the #36 NG orifice

supplied in the installation manual bag. Pipe dope or other

approved gas line sealant will need to be applied before insert-

ing into bulkhead. The foil sticker supplied, stating RDV33,

will need to be affixed over the model name RDV40 on the

serial number label (located in the control compartment).

b

riCk

p

anel

& l

og

s

et

i

nstallation

If logs are not installed according to the log installation

instructions, flame impingement and improper combustion

could occur and result in soot and/or excessive production of

carbon monoxide (CO), a colorless, odorless, toxic gas.

The size and position of the log set is critical to achieve a

safe, reliable and attractive flame pattern. Any attempt to

use a different log set in the fireplace will void the warranty

and will result in incomplete combustion, sooting, and poor

flame quality.

1. Remove the log rack (2 screws) and install the rear log

on the retainer.

Retainer

Rear log

2. Place the rear brick panel on the brackets and reinstall the

log rack with the rear log. IMPORTANT!!! SCREWS PASS

THROUGH THE LOG RACK AND THE BURNER PAN.

3. Install the side brick panels by sliding them into place.

Side Brick Panels

Figure 7

Figure 8

Figure 9

2 Screws