WARNINGS

Improper installation, adjustment, alteration,

service or maintenance can cause injury or

property damage. For assistance or additional

information, consult a qualified installer, service

agency or your gas supplier.

Operation of this appliance when not connected

to a properly installed and maintained venting

system can result in carbon monoxide (CO)

poisoning and possible death.

Carbon monoxide poisoning – early signs of

carbon monoxide poisoning resemble the flu

with headaches, dizziness, or nausea. If you

have these signs, get fresh air at once! Have the

heater inspected by a qualified service techni-

cian. Some people are more affected by carbon

monoxide than others. These include pregnant

women, people with heart or lung disease or

anemia, those under the influence of alcohol,

and those at high altitudes.

5. Locate the pilot by looking over the top of the left front

log. A blue flame will be seen when the pilot is lit.

6. Turn the gas control knob counter-clockwise to

the "PILOT" position.

7. Push the knob all the way in and hold in that position.

Immediately light the pilot by pressing the igniter button

several times until pilot is lit. Continue to hold the knob

in for about 30 seconds after the pilot is lit. Realease

knob and it will pop back out. Pilot should remain lit. If it

goes out, repeat steps 4-8 holding knob in an additional

15 seconds after pilot is lit. If knob does not pop out

when released, stop and immediately call your service

technician or gas supplier. If the pilot will not stay lit after

several tries, turn the gas control knob to "OFF" and call

your service technician or your gas supplier.

8. After pilot is lit, turn gas control knob counter-clockwise

to "ON." Knob can only be turned to "ON" if the

knob has popped out.

9. To turn burner on, turn "ON/OFF" rocker switch to "ON"

or set the thermostat to the desired temperature above

room temperature.

10. Adjust the flame height (and heat output) by turning the

flame height knob clockwise for full flame and

counter-clockwise for reduced flame.

11. Turn on the electric power to the appliance and set the

blower to the desired air flow after it turns on when the

appliance reaches operating temperature.

TO TURN OFF GAS TO APPLIANCE

1. Turn off the "ON/OFF" rocker switch and/or thermostat (if

installed) to its lowest setting.

2. Turn off electric power to the appliance if service is to

be performed.

3. Push in gas control knob slightly and turn clockwise

to "OFF." Do not force.

This appliance needs fresh air for safe operation and

must be installed so there are provisions for adequate

combustion and ventilation air.

SHUTDOWN PROCEDURE

To turn off the burner, turn the rocker switch to "OFF" or

adjust the thermostat (if installed) to a setting below room

temperature. The pilot will remain lit for future burner igni-

tion. For complete shutdown, see "TO TURN OFF GAS TO

APPLIANCE" above.

PILOT ASSEMBLY

Thermopile

Veilleuse à gaz Igniter (electrode)

Allumeur

Thermocouple

Gas Pilot Hood

Robertshaw Millivolt Gas Valve

TP/TH

TH

TP

Gas Control Knob

(Pilot / On / Off)

O

FF

O

N

Piezo Igniter

Allumeur

ON/OFF Switch

Interrupteur

Flame Height Control

Knob (HI/LO)