Troubleshooting & repair, Plug j6, Power board voltage test (continued) – Lincoln Electric INVERTEC V250-S User Manual

Page 60

Advertising
background image

F-28

TROUBLESHOOTING & REPAIR

F-28

TEST PROCEDURE

1. Remove main input power to the

V250-S.

2. Perform

Filter Capacitor Discharge

Procedure detailed in Maintenance
Section.

3. Locate and familiarize yourself with

the leads and pin locations in plug J6
on the power board. See Figure F.8.

4. The following tests will be performed

with the input power applied to the
V250-S. BE CAREFUL. ALWAYS
REMOVE INPUT POWER AND
PERFORM FILTER CAPACITOR
DISCHARGE PROCEDURE
BEFORE TOUCHING ANY
MACHINE COMPONENT.

5. Apply input power and turn On the

V250-S.

6. Perform the voltage checks outlined

in

Table F.4. making sure all of the

test conditions are in effect.

POWER BOARD VOLTAGE TEST (continued)

INVERTEC V250-S

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

V250S POWER G2684

DANGER

HIGH VOL

T

AGE CA

N

204

201

209

208

205

207A

20

203A

2

+

+

J6

PLUG J6

#308 (1J6)

#307 (2J6)

#309 (6J6)

#310 (3J6)

#311 (4J6)

#313 (5J6)

Figure F.8 Plug J6 on Power Board