TROUBLESHOOTING & REPAIR

F-32

INVERTEC V250-S

TEST PROCEDURE

1. Remove main input power to the

V250-S.

2. Perform

Filter Capacitor

Discharge Procedure detailed in
Maintenance Section.

3. Locate and familiarize yourself with

the leads and pin locations in plugs
J1 thru J5 on the control board. See
Figure F.9.

4. The following tests will be performed

with the input power applied to the
V250-S. BE CAREFUL. ALWAYS
REMOVE INPUT POWER AND
PERFORM FILTER CAPACITOR
DISCHARGE PROCEDURE
BEFORE TOUCHING ANY
MACHINE COMPONENT.

5. Apply input power and turn ON the

V250 -S.

6. Perform the voltage checks outlined

in

Table F.5. making sure all of the

test conditions are in effect.

CONTROL BOARD VOLTAGE TEST (continued)

G2666-[ ]

V250S CONTROL

J1

J2

J5

J3

J4

1J1

(RED LEAD)

3J1

(RED LEAD)

4J5

(#318)

1J5

(#322)

2J4

(WHITE LEAD)

1J4

(BLACK LEAD)

7J3

(#303)

1J3

(#375)

Figure F.9 Plugs J1-J5 on Control Board