Framing specifications – Lennox Hearth ELITE SERIES LBC-3824 User Manual

Page 7

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

7

Note: The framed depth, 25-1/2" (648 mm)
from a framed wall, must always be measured
from a finished surface. If a wall covering such
as drywall is to be attached to the rear wall,
then the framed depth must be measured from
the drywall surface. It is important that this
dimension be exact.

If the appliance is to be elevated above floor
level, a solid continuous platform must be
constructed.

The header may rest on the top metal spacers,
but must not be notched to fit around them.

Consult all local codes.

Figure 11

Figure 12

Framing Dimensions for Ceiling

Flue Type

A

B

FTF10 Vertical

19"

19"

(483 mm)

(483 mm)

FTF10

19"

29"

Offset 30

°

(483 mm)

(737 mm)

Figure 13

Framing Dimensions for Roof

Pitch

C

D*

0/12

19"

19"

(483 mm)

(483 mm)

6/12

19"

22"

(483 mm)

(559 mm)

12/12

19"

27"

(483 mm)

(686 mm)

* Perpendicular to roof ridge

Figure 15

Figure 16

Figure 14

Note: All framing dimensions calculated for 1/2"
dry wall at the fireplace face. If sheathing the
chase or finishing with other thickness materials,
calculations will need to be made.

FRAMING SPECIFICATIONS

FOAK-4 Combustion

Air Kit

G

A

J

Outside Chase

Back Wall of Chase/Enclosure

Including Finishing Materials

if any

Rough Framing Face
(Unfinished Shown)

A

E

F

D

C

K

Back Wall of Chase/Enclosure
Including Finishing Materials
if any

Rough

Framing Face

(Unfinished Shown)

Corner Installation

FOAK-4 Combustion

Air Kit

A

B

Ceiling Framing

C

D

Roof Framing

Header

Fireplace Framing

B

A

Framing Dimensions

Fireplace Opening Width

38

43

A

48-1/8"

52-7/8"

(1222 mm)

(1343 mm)

B

50"

50"

(1270 mm)

(1270 mm)

C

26-1/4"

31"

(667 mm)

(787 mm)

D

13-1/8"

15-1/2"

(334 mm)

(394 mm)

E

77-1/4"

82"

(1962 mm)

(2083 mm)

F

38-5/8"

41"

(981 mm)

(1041 mm)

G

25-1/2"

25-1/2"

(648 mm)

(648 mm)

J

11"

11"

(279 mm)

(279 mm)

K

54-5/8"

58"

(1388 mm)

(1473 mm)

A

G

Inside Chase

Back Wall of Chase/Enclosure

Including Finising Materials if any

Rough

Framing Face

(Unfinished

Shown)

FOAK

Combustion

Air Kit

Advertising