Lennox Hearth BRENTWOOD LV User Manual

Page 16

Advertising
background image

Aluminum Tape

Aluminum Tape

Fireplace

Connection

Plastic

Cover

Insulation

Flexible Pipe

Fireplace

OUTSIDE AIR CONNECTION TO THE FIREPLACE

Figure 26

OUTSIDE AIR KIT - REQUIRED (Included w/fireplace)

During operation, the fireplace requires fresh air for combustion and

draws air out of the house. It may starve other fuel burning appliances

such as gas or oil furnaces. As well, exhaust blowers may compete for

air, causing negative pressure in the house, resulting in smoke entering

the house from the fireplace. This situation is aggravated in modern

airtight houses. To overcome this problem, we strongly recommend that

you install an outside air assembly. Check with local authorities having

jurisdiction in your area, it may be mandatory.

NOTE: Should you decide not to install the outside air assembly,

proceed as follows:

- Remove the bottom grill. The air box is located on front left and is on

a slant.

- Unscrew the four screws holding the inside air box covering plate and

remove it.

Outside Air Installation

The outside air assembly may be installed according to the following

requirements:

A) Duct length should be kept to a minimum. The maximum length of

duct is twenty (20) feet (6.1 m) for a 4 in. dia. pipe (See note below).

B) The air intake register must not be installed more than ten (10) feet

(3050 mm) above the base of the fireplace.

C) The fresh air must come from outside the house. The air intake must

not draw air from the attic, from the basement or garage.

D) The air intake should be installed where it is not likely to be blocked by

snow or exposed to extreme wind and away from automobile exhaust

fumes, gas meters and other vents.

E) The duct and register may be installed above or below floor level.

The following components are required:

- Outside air kit (UZI) (includes 4 inch flex that goes up to ten (10) feet

long)

- 4” Adaptor for fireplace connection (supplied with the unit)

Make a 4-1/4” (110 mm) hole in the outside wall of the house at the chosen

location. From outside, place the outside air register in the hole (open

side down) and fasten the register to the wall, with screws as shown (see

Figure 25). Slip the pipe into the insulated sleeve. Place the insulated

pipe over the register tube and over the fireplace’s outside air connector

(see Figure 26). At each end, carefully pull back the insulation and plastic

cover exposing the flexible pipe. Using the aluminium tape provided,

wrap the tape around the joint between the flexible pipe and the air inlets.

Carefully push the insulation and plastic cover back over the pipe. Using

aluminium tape, fasten the plastic cover in place.

NOTE: We recommend not to exceed 20 feet of 4” flexible pipe. If you

require a longer length we recommend that you use a 5” diameter flex-

ible pipe for the complete run up to 30 feet and a 6” diameter pipe for a

run of up to 40 feet.

Figure 25

OUTSIDE CONNECTION

Outside

Intake

Screw

Opening

Facing

Down

Wall

Aluminum Tape

Plastic Cover

Insulation

Flexible Pipe

Aluminum Tape

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

16

Advertising