Lennox Hearth BRENTWOOD LV User Manual

Page 27

Advertising
background image

Fireplace Model Brentwood™ LV - Approved Venting Components

manufactured by Security Chimneys International™ only.

6” diameter chimney - AC (air cooled), Secure Temp

®

ASHT (or

Nova Temp

®

HT6103+) and Secure Temp S-2100+ (or Nova Temp

HT6000+).

6” diameter chimney for relining masonry chimneys - Tubinox™

chimney (or Projet

®

SS), 6” diameter with adaptor for installation in

a masonry chimney.

Secure Temp ASHT 1” High Temp. Insulated Stainless Steel Chimney

6” I.D and 8” O.D., Double-Wall Stainl. Steel, Listed to CAN/UCL-S604 and UL-103HT

Description

Part/Cat. No.

Lengths and Misc. Chimney Components

8” length, 6” Dia., 6L8

6L8

12” length, 6” Dia., 6L12

6L12

18” length, 6” Dia., 6L18

6L18

24” length, 6” Dia., 6L24

6L24

36” length, 6” Dia., 6L36

6L36

48” length, 6” Dia., 6L48

6L48

Adjustable Length 12”, 6” Dia., 6LA

6LA

15º elbow, 6” Dia., 6E15

6E15

30º elbow, 6” Dia., 6E30

6E30

Rain Termination Cap, 6” Dia., 6CC

6CC

Spark Arrester Screen (universal spark arrester band), PE

PE

Wall Band, BM

BM

Supports

Offset Support, SO

SO

Roof Support, ST

ST

Roof Brace, BS2

BS2

Firestops

Firestop, 6BF

6BF

Radiation Shield, 6RS

6RS

Insulated Attic Radiation Shield, 6RSA

6RSA2

Insulated Wall Radiation Shield, 6RSM

6RSM

Insulated Wall Radiation Shield, 30º, 6RSMI30

6RSMI30

Uninsulated Wall Radiation Shield, 30º, 6RSM30

6RSM30

Attic Radiation Shield

H0487

Roof Flashings

Flat Roof Flashing, 6FR

6FR

1/12 - 7/12 (5º - 30º), 6FAR

6FAR

8/12 - 12/12 (30º - 45º), 6FBR

6FBR

Storm Collar, 6FC

6FC

NOTES:

j

Nova Temp

HT6000+ is equivalent to Secure Temp

S-2100+

k

Nova Temp

HT6103+ is equivalent to Secure Temp

ASHT

l

This appliance is equipped with the ASHT Chimney Adaptor. When other
chimney is used, a chimney adaptor for that chimney will be required.

m

Chimney Adaptor (S-2100+ / HT6000+) for CANADA ONLY - If you want to

install a S-2100+ / HT6000+ chimney, an adaptor is available (6UCA).

n

AC Chimney is NOT recommended at elevations above 4,000 feet or in cold
climates (climates where temperatures will fall below 32° F / 0° C). When
using AC chimney, an AC6SB starter section must be used before installing
an elbow. When an offset is needed immediately off the top of the fireplace,
an elbow starter section, AC6SB30 (H3780), is available.

SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS

The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering

information.

Security Chimneys International Limited
2125 Monterey, Laval, Quebec
Canada, H7L 3T6
www.securitychimneys.com

450-973-9999
1-800-361-4909 (USA)
1-800-667-3387 (Canada)

27

Advertising