S)43, Aas)42 – Lucent Technologies 108286063 User Manual

Page 12

Advertising
background image

Change Descriptions

10

Issue 2 May 1998

34. Turning off TTI did not remove ports that were administered by TTI on

cabinets that had been removed, causing translation corruption.

35. Automatic caller information was not displayed if the agent was not in the

first split that the call was queued to.

36. DCS transparency was lost because DCS calls saved all processed

message buffers for the duration of the call, causing a shortage of DCS
message buffers in the switch. Now, the number of messages saved per
DCS calls is limited so that more messages are available for other calls,
thereby reducing the chances of running out of message buffers resulting
in a loss of DCS transparency.

37. Some voice calls on TN767 DS1 circuit packs were randomly considered

as data calls, so data tone was connected on these calls and cut-through
trunk operation was not allowed.

38. CO-to-CO calls (DID calls that forwarded off-net or that were transferred

off-net) could have a transmission level that was too high. This caused
instability on these calls at some customer sites.

39. The Adjunct Supervision field did not work correctly when it was set to a

VMI set type.

40. Using an abbreviated dialing button for end-to-end signaling was possible

only from the originating station or after a trunk flash when the call
included a single trunk that was administered to support trunk flash. It did
not work from a terminating station under other circumstances. Now, a
terminating station can use an abbreviated dialing button to do end-to-end
signaling on any facilities that can generate the tones.

41. Page 5 of the display capacity form showed an incorrect system limit for

the queue-status buttons.

42. A trunk caller was blocked from picking up another trunk call using TAAS if

both trunks were in the same trunk group.

43. The message "Entry is bad" was displayed on the SAT when executing a

clear-amw-all-extension command. Now, the message "Command
successfully completed" is displayed if the clear-amw-all-extension
command is successful. Otherwise, the message "Error encountered,
can’t complete request" is displayed.

44. If there were about 200 or more long holding-time trunk calls in the system,

ACA caused a system restart.

45. The logged-in agent count in the display-system-capacity form was

sometimes higher than the number of agents actually logged in. Now, the
count always reflects the actual number of agents logged in.

46. When the "Display Authorization Code?" field was set to n, using an

authorization code from a bridged appearance caused other bridged BRI
stations to lose these dial keypad functions: touch-tone feedback, local
dialed digit display, and retention for redial. Now, these functions are only

Advertising