BEFORE CALLING FOR SERVICE

(cont.)

T RO U B L E S H O OT I N G

Problem

Possible Causes

Solutions

Steam doesn’t

generate but no error

code is shown.

• Water level error.

• Unplug dryer and call for service.

Garments still

wrinkled after

Steam FreSh

.

• Too many or too different

types of garments in dryer.

• Small loads of 1 to 5 items work best.
• Load fewer garments. Load similar-type garments.

there are no creases

left on garment after

Steam FreSh

.

• The function of this cycle

is to remove wrinkles from

fabric.

• Use an iron to make creases.

Garments have

static after reDUCe

StatIC.

• This is normal.

• Depends on individual moisture level in skin.

Garments are too

damp or too dry after

reDUCe StatIC.

• Correct drying options not

selected.

• Select load weight manually before starting

REDUCE STATIC option.

Garments are not

uniformly damp after

eaSY IrON.

• This is normal.

• Depends on the amount or type of garments.

Water drips from door
during Steam Cycle.

• This is normal.

• This is steam condensation on door surface.

Steam is not visible

during Steam Cycle.

• This is normal.

• Steam vapor is difficult to see when the door is

closed.

Drum does not turn

during Steam Cycle.

• This is normal.

• The drum is turned off so that the steam vapor

remains in the drum.

Cannot see steam

vapor at the

beginning of cycle.

• This is normal.

• Steam is released at different stages of the cycle

for each option.

• MORE TIME button pressed.

Odors remain in

clothing after

Steam FreSh

.

• STEAM FRESH

did not

remove odor completely.

• Fabrics containing strong odors should be

washed in a normal cycle.

the display shows

BULKY LOaD.

• Pressing the MORE TIME button several times will

set the cycle for a large load such as a comforter.

2 bars are displayed
In the LCD screen.

• Ductwork is slightly too

long or has too many

turns/restrictions.

• Partial blockage of the

ductwork due to lint buildup.

• sInstall a shorter or straighter duct run. See the

Installation Instructions.

• Ductwork should be checked/cleaned soon.

Dryer can be used in this condition, but drying times

may be longer.

• If “END OF CYCLE” is displayed after the end of

cycle, it will be off in 4 minutes. If POWER button

is pressed or the door is opened, power will be off

immediately.

4 bars are displayed
In the LCD screen.

• Ductwork is too long or has

too many turns/restrictions.

• Significant blockage of the

ductwork due to lint buildup

or debris.

• Install a shorter or straighter duct run. See the

Installation Instructions.

• Ductwork should be checked/cleaned soon.

Dryer can be used in this condition, but drying times

may be longer.

• If “NEED FLOW CHECK” is displayed after the end

of cycle, it will be off in 2 hours. If POWER button

is pressed or the door is opened, power will be off

immediately.

END OF CYCLE

THE DUCTWORK HAS

A BLOCKAGE THAT NEEDS

TO BE REMOVED

IMMEDIATELY.

NEED FLOW CHECK