0 specifications – Lindy RS-422/485 User Manual

Page 5

Advertising
background image

‹ 4.0 Specifications

4.1 Function

Type

LINDY Industrial Host Controller

Mode of Operation

Differential

RS-422 Full-Duplex

Bus Transceivers

RS-485 Half-Duplex

RS-422 1 Driver

Drivers per Line

RS-485 10 Drivers

RS-422 10 Receivers

Receivers per Line

RS-485 32 Receivers

4.2 Hardware

IC

SUN1889

Controller

UART (16C650 compatible)

Bus Interface

64 Bit & 32 Bit PCI Bus, 3.3V & 5V connector keys

51200: 2 ports

51202: 4 ports

Number of Ports

51204: 8 ports

Connector

51200: 2 x DB9 Male

51202: 1 x DB37 Female to 4 x DB9/Male

51204: 1 x DB78 Female to 8 x DB9/Male

4.3 Communication

IRQ & I/O address

BIOS assigned

FIFO

32 byte hardware FIFO

128Kbyte software FIFO

RS-485 Signal Control

ARSC™ technology

Select RS-422/485

Auto Switch RS-422/485 technology

Baud rate

75bps ~ 921.6 Kbps

Data bit

4,5,6,7,8

Stop bit

1,1.5,2

Parity

even, odd, none, mark, space

Flow Control

None, Xon/Xoff, Hardware

RS-422

TxD+/-, RxD+/-, RTS+/-, CTS+/-, GND

Data Signal

RS-485

Data+/-, RTS+/-, CTS+/-, GND

- 3 -

Advertising