LG MODEL STRIKER S160 User Manual

Page 7

Advertising
background image

7

Diagram B: Side View-Alcove & Parallel Installation

Diagram A: Top View-Parallel Installation

K

B

A

E

C

D

*L

K

Floor Protection

Floor Protection

Floor Protection

G G

F

F

72" Min.

H

I

M

J

I

J

H

E

E

L

48”

Maximum

Depth

Diagram C: Top

View-Corner

Installation

N

P

T

Installation Clearances - Refer to Diagrams A, B and C

PIPE

INSTALLATION

A

B (1)

C

D (1)

E†

F (1,4)

G (4)

6” Single
Wall

Residential or
Alcove

USA-16”

CAN-48mm

14”

56mm

USA-1”

CAN-610mm

1-1/”
18mm

8”

00mm

9-/4”

48mm

USA-18”

CAN-5mm

6” Single w/
Pipe Shield

Residential or
Alcove

USA-10”

CAN-0mm

8”

00mm

USA-18”

CAN-5mm

9-1/”

41mm

8”

00mm

5-1/”

140mm

USA-1-1/”
CAN-419mm

6” Double
Wall

Residential or
Alcove or Mobile
Home*

USA-10”

CAN-0mm

8”

00mm

USA-18”

CAN-5mm

9-1/”

41mm

8”

00mm

5-1/”

140mm

USA-1-1/”
CAN-419mm

PIPE

INSTALLATION

H ()

I (6)

J ()

K

L (5)

M

Single Wall Residential or

Alcove

USA--/4”

CAN-1111mm

USA-47-/4”

CAN-140mm

USA--1/”

CAN-100mm

USA-16”

CAN-450mm

USA 0"

CAN-00mm

84”

14mm

Single w/
Pipe Shield

Residential or
Alcove

USA--/4”

CAN-1111mm

USA-41-/4”

CAN-1188mm

USA--1/”

CAN-100mm

USA-16”

CAN-450mm

USA 0"

CAN-00mm

84”

14mm

Double Wall
Air-Cooled

Residential or
Alcove or Mo-
bile Home*

USA--/4”

CAN-1111mm

USA-41-/4”

CAN-1188mm

USA--1/”

CAN-100mm

USA-16”

CAN-450mm

USA 0"

CAN-00mm

7”

189mm

† USA=8" (00mm) from door opening,
Canada=8" (00mm) from sides and back
of unit

u

Dimensions to Stove Body

* Mobile Home - USA only

PIPE

INSTALLATION

Nu

Pu

T (6)

Single Wall Residential or

Alcove

0"

76mm

6"

914mm

USA-58-1/”

CAN-1645mm

Single w/
Pipe Shield

Residential or
Alcove

0"

76mm

6"

914mm

USA-5”

CAN-1486mm

Double Wall
Air-Cooled

Residential or
Alcove or Mo-
bile Home*

0"

76mm

6"

914mm

USA-5”

CAN-1486mm

Footnotes:

1- These dimensions to the stove body are for reference only. Actual

distances should be measured from the stove’s flue collar.

2- Minimum noncombustible hearth pad dimensions.

3- Shield shall be attached to the rear of the stove pipe with a 1” air

space and must run from the top of the stove to the ceiling.

4- Not applicable to alcove installations.

5- In corner applications, when installed at minimum back wall clear-

ances, the required floor protection is dimensioned off the back

plane of the stove, therefore the floor protection required off the

back corners (at a 45 degree angle) only needs to extend to the

wall. This situation will only occur in CANADA installations.

6- Reference dimension only, to assist in planning the installation.
Clearances to connector pipe shall be measured from the flue
collar of the stove.

Diagram C: Top View -

Corner Clearance,
Stove and Flue to Wall

6” Ø

Flue Collar

Advertising