17

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

Check voltage on AC terminals of module. The value should be around 24 VAC.
Confirm that wire connections are secure.

Check for visible cracked casing, cuts, etc.

Check pilot assembly for visibly broken spark electrode, etc.

Check voltage on D.C. terminal of batteries. The value should be around 3.0V.

Ensure that the gas supply is turned on.

Ensure sensor wire connection is secure to purple wire of ignition control.

Ensure blue and white (2) wire connection is secure to valve.

Purge gas line of air.

Test voltage at AC terminals of module for 24 VAC. If no voltage, replace
module.

Check electrical connections between module and gas control. If okay, replace
gas control (valve).

Turned gas supply to "ON".

Check wire connection.

Check location of sensor.

Check vent system for obstructions.

Check for proper log placement.

Check for proper air shutter openings.

A. Low voltage/or bad lead

wires.

B. Damaged igniter wire.

C. Damaged pilot assembly.

D. Batteries Low.

A. No fuel supply.

B. Loose sensor wire.

C. Lose wires to valve.

D. Air in the gas line.

E. Low voltage..

A. Gas supply is turned

"OFF".

B. Loose wire connection

on valve or ignition
module.

C. Flame does not engulf

flame sensor.

D. Obstructed vent system.

A. Flame impingement on

the log.

B. Improper air shutter

opening.

1. Nothing happens when

ON/OFF switch is turned
on (pilot does not
spark).

2. The main burner does

not light and the igniter
is sparking.

3. The main burner come

"ON" but then go "OFF".

4. The log and glass soot.

Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall
switch are in the “ON” position.

Important: Valve system troubleshooting should only be accomplished by a qualified service technician.