NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Figure 5

CAUTION: DO NOT ATTEMPT TO TOUCH THE
DOORS WITH YOUR HANDS WHILE THE FIRE-
PLACE IS IN USE. ALWAYS USE DOOR
HANDLES. DOORS WILL BECOME VERY HOT
WHEN FIREPLACE IS IN USE.

Figure 3

Figure 2

2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This is
due to the “burn-in” of internal paints and
lubricants used in the manufacturing process.

3. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due to
excessive lint from carpeting, bedding materi-
als, etc. It is important that control compart-
ments, burners and circulating air passage-
ways of the appliance be kept clean.

4. Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re-light-
ing, refer to the lighting instructions in this
manual. Instructions are also found on a pull-
out panel located on the floor of the appliance.

5. Always keep the appliance area clear and
free from combustible materials, gasoline and
other flammable liquids.

6. Remember, Millivolt appliances have a con-
tinuous burning pilot flame. Exercise caution
when using products with combustible vapors.

7. Clean the optional glass doors only when
necessary. Wipe surface with clean, damp-
ened, soft cloth. Follow with dry, soft towel as
desired. Take care not to scratch the glass
surface.

Figure 4

DAMPER AND OUTSIDE AIR CONTROLS

This appliance is fitted with a manually con-
trolled vent damper. The vent damper should
be closed when the appliance is not in use to
prevent cold air from entering the home through
the venting system. The damper is controlled
through the use of a control lever located within
the appliance opening at the top center in front
of the firebox lintel

(see Figure 5 ). The control

lever snaps into place at either extreme of its
range of motion. When locked in position all
the way to the right, the damper is open. When
locked in position all the way to the left, the
damper is closed.

The damper lever actuates a switch, (see wir-
ing diagram) which will prevent the appliance
main burner from lighting unless the damper
is locked open. The appliance flue damper
must always remain open when operating.

Fully Open or
Fully Closed

WARNING: DO NOT USE ABRASIVE
CLEANERS. NEVER CLEAN THE GLASS
WHEN IT IS HOT.

WARNING: FIREPLACES EQUIPPED
WITH OPTIONAL ACCESSORY DOORS
SHOULD BE OPERATED ONLY WITH
THE DOORS FULLY OPEN OR FULLY
CLOSED

(FIGURE 4 ). THIS APPLI-

ANCE MAY ONLY BE FITTED WITH
DOORS CERTIFIED FOR USE WITH THE
APPLIANCE.

AVERTISSEMENT: POUR UTILISATION
UNIQUEMENT AVEC LES PORTES EN
VERRE CERTIFIÊES AVEC L'APPAREIL.

WARNING: DAMPER MUST BE IN OPEN
POSITION WHEN APPLIANCE MAIN
BURNER IS OPERATING.

AVERTISSEMENT: LE REGISTRE DOIT
ÊTRE EN POSITION OUVERTE LORSQUE
LE OU LES BRULEURS PRINCIPAUX DE
L'APPEREIL FONCTIONNMENT.

SIT Millivolt Valve

Gas Control
Knob

Piezo
Ignitor

E

A

TPTH

TP

TH

PILO

T

PIL

O

T

ON

it

OFF

Locked
Open

Locked

Closed

Outside Air

Actuator

Inlet Gauge Port

Pilot Adjustment Screw

Manifold Gauge Port