NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Non-concealed gas connections may be made using the

entry points at either end of the firebox or the one in

the bottom of the firebox . A concealed gas connection

may be made using the knock out hole in the center

back of the firebox . Select the most appropriate entry

point and knock out the rel evant hole in both the firebox

and the outer casing .

No more than 59" of 1/4" diameter pipe must be used

to avoid unnecessary pressure drops .

If a concealed gas con nection is to be made, the supply

pipe should always be sleeved through walls and floors

using the shortest possi ble route .

For concealed supply pipe routing, pipes must (where

possible) be ver tical and providing there is sufficient

wall thick ness available, they should be placed in pipe

chases . Horizontal pipe runs should be avoided where

possible . Prior to chasing a solid wall, an inspection

should be made to note the proximity of any cables/

sockets outlets which may already be buried . Pipes

must be secured using suitable clips and protected

against corrosion . Ideally factory finished protected

pipe-work and fittings should be used . Joints should

be kept to a minimum and compression fittings must

not be used . The pipe-work installation must be tested

for soundness before any protection is applied and/or

the pipe-work and fittings are buried .

1. Remove the Grill.

Note: This design of grill

not fitted to widescreen

model

2. Remove retaining

wing nuts

3. Remove

spindle

retaining pin

4. Remove control indicator bracket and control knob

Note : X-Fire 1000

shown as example

5. Widescreen

models : Remove

two self-tapping

screws from the

Left hand side of

the outer casing

and one from the

right hand side.

Figure 2

PREPARING THE APPLIANCE

IMPORTANT NOTE: All gas piping must be done by a

licensed plumber or gas fitter and must conform to

the requirements of the National Fuel Gas Code NFPA

54 / ANSI Z223.1 - latest edition.

1 . Remove the two retaining screws on each side of

the upper grill and remove the grill from the outer

casing .

2 . Remove the two retaining wing nuts from the retaining

studs that protrude into the lower part of the main

firebox as shown . The control knob is located on

the lower right hand side of the outer casing, and

is mounted in an indicator bracket, which has a

metallic indication ‘pip’ (indication mark for proper

knob alignment) . Both the knob and the indicator

bracket should be removed as follows;

3 . Remove the retaining pin from the gas valve spindle

and withdraw the control knob and the spindle exten-

sion from the right hand side of the appliance .

4 . Remove the four retaining screws and the indicator

bracket . The firebox may now be detached from the

outer casing .