Lincoln, Warranty, Ventilation requirements – Lincoln Impinger Conveyorized Oven 3270 User Manual

Page 2: Global

Advertising
background image

Global

Lincoln

Warranty:

All 3200 series Impinger

®

ovens installed in the United States and Canada come with a two (2) year parts and

labor warranty starting from the date of start-up/check-out. All ovens installed in locations other than the US
and Canada are warranted for one (1) year parts and ninety (90) days labor starting from the date of start-up/
check-out. Start-up/check-out must occur within eighteen (18) months of date of manufacture.

General Information | 3255 Natural Gas Ovens:

General Information | 3270 Natural Gas Ovens:

General Information | 3255 Propane (LP) Gas Ovens:

General Information | 3270 Propane (LP) Gas Ovens:

Burner Capacity

BTU/hr (MAX)

Voltage

Hertz

Phase

Amps

Gas Supply Pressure

Inches, Water

Column

Gas Pipe

Size (NPT)

Single Oven

145,000

120

60

1

7

8”-14”

1”

Double Stack

290,000

120

60

1

14

8”-14”

1¼”

Triple Stack

435,000

120

60

1

21

8”-14”

1½”

Burner Capacity

BTU/hr (MAX)

Voltage

Hertz

Phase

Amps

Gas Supply Pressure

Inches, Water

Column

Gas Pipe

Size (NPT)

Single Oven

160,000

120

60

1

14

8”-14”

1”

Double Stack

320,000

120

60

1

28

8”-14”

1¼”

Triple Stack

480,000

120

60

1

42

8”-14”

1½”

Burner Capacity

BTU/hr (MAX)

Voltage

Hertz

Phase

Amps

Gas Supply Pressure

Inches, Water

Column

Gas Pipe

Size (NPT)

Single Oven

145,000

120

60

1

7

11.5”-14”

¾”

Double Stack

290,000

120

60

1

14

11.5”-14”

1”

Triple Stack

435,000

120

60

1

21

11.5”-14”

1¼”

Burner Capacity

BTU/hr (MAX)

Voltage

Hertz

Phase

Amps

Gas Supply Pressure

Inches, Water

Column

Gas Pipe

Size (NPT)

Single Oven

160,000

120

60

1

14

11.5”-14”

¾”

Double Stack

320,000

120

60

1

28

11.5”-14”

1”

Triple Stack

480,000

120

60

1

42

11.5”-14”

1¼”

Ventilation Requirements:

Ventilation is required. Local codes prevail. These are the “authority having jurisdiction” as stated by the
National Fire Protection Association, Inc. in NFPA 96-1994. Consult the Impinger® 3255/3270 Installation and
Operations Manual for ventilation recommendations.

Advertising