932 Tab (SPA962 only)

Unit 1

Field

Description

Unit 1 Key 1-32

This field lets you enter a string that defines the extension and other parameters associated
with each lighted button on the first SPA932 unit. Keywords and values are case-sensitive.
The configuration script is composed of the following keywords, followed by an equal
sign (=) and separated by semicolons (;):

•

fnc—defines which of the following functions are enabled for the specified key
(separate more than one function with a plus sign (+):

–

blf—busy lamp field function used for monitoring line activity

–

sd—speed dial function

–

cp—call pickup (if supported by the SIP proxy server)

•

sub—Use this keyword to identify the phones to be monitored.

•

usr —Use this keyword to identify the specific users or extensions to be monitored.

•

nme—(optional) Use this field with the SPA9000 to identify any alias that has been
assigned to the extension in the Linksys IP phone configuration.

•

vid—(optional) Use this field to identify the SPA962 extension to use with the
monitored list specified by the sub= keyword, when more than one BLF monitored
list is configured on the SIP proxy server. The possible values are 1 to 6,
corresponding to each of the six extensions available on the SPA962.

Note

You only need to use the vid= keyword in the first entry assigned to each
SPA962 extension. Subsequent keys will use the same extension.

The following is the syntax for a Broadsoft server:

fnc=enabled_functions;sub=blf_list_uri@broadsoft;usr=dn@broadsoft

Replace the variables (in italics), as follows:

•

enabled_functions with cp for call pickup, sd for speed dial, and blf for busy lamp
field; separate multiple functions in any order with a plus sign (+)

•

blf_list_uri

with the URI assigned to the BLF monitoring list on the Broadsoft

server.

•

broadsoft

with the IP address or hostname of the Broadsoft server.

•

dn

with the number associated with the user account on the Monitored Users list.

For example:

fnc=sd+blf;[email protected];[email protected]

Note

The nme keyword is not used because the Broadsoft server automatically uses the
assigned user account name.