Notice, Confirm the refrigerant – LG LS305HV User Manual

Page 10

Advertising
background image

10 Room Air Conditioner

Installation

1. Check the quality label on the indoor and outdoor unit.

2. Make certain that the refrigerant is R-410A.

THIS PRODUCT CONTAINS R-410A REFRIGERANT

1) Different compressor oil

- R-410A(Polyol ester) / R-22(Mineral).
- Do not mix the existing mineral oil.
- Do not apply used pipe, tools and gauges covered with the existing mineral oil.

2) Absorption of moisture

-Compressor’s oil has the high absorption rate of moisture.

3) Composition

- R-410A(R32:R125=50:50wt%).
NOTE: Never mix with other refrigerants

4) High pressure.

- 1.6 times higher than R-22.
- High Pressure refrigerant may cause personal injury.

Do not handle the pipe by yourself (customer) High-pressure refrigerant may cause personal injury.
- manifold gauge ,charging and any piping tools must be dedicated to R-410A systems.

NOTICE

Confirm The Refrigerant

Example : Split type 12,000 Btu/h

120

100

100%

100%

70%

50%

30%

0%

70%

50%

30%

0%

100

93

89

84

76

80

60

40

20

0

R-410A
R-22

Boiling Pt.(°C)

Vapor pressure(25°C)(kg f/cnf)

Vapor density(25°C)(kg/m

2

)

R-410A

-51.4

15.9

64

R-22

-40.8

9.6

44.4

Advertising