Specifications, 5 and 8 ton split systems – Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2 User Manual

Page 11

Advertising
background image

60 Hz

50 Hz

AIR COOLED SYSTEM

w/Outdoor Condensing Unit

w/Centrifugal Condensing Unit

w/Outdoor Condensing Unit

w/Centrifugal Condensing Unit

5 Tons

5 Tons

5 Tons

5 Tons

Evaporator

MMD60E

MMD60E

MMD59E

MMD59E

Condensing Unit

PFH067A

MCD65A

PFH066A

MCD64A

Net Capacity Data*-BTUH (kW)
80 F (26.7 C) DB

Total

65,000 (19.0)

66,200 (19.4)

65,400 (19.2)

65,500 (19.2)

50% RH

Sensible

54,400 (15.9)

54,800 (16.1)

54,800 (16.1)

54,800 (16.1)

75 F (23.9 C) DB

Total

60,500 (17.7)

61,800 (18.1)

60,000 (17.6)

61,000 (17.9)

50% RH

Sensible

52,600 (15.4)

53,100 (15.6)

52,600 (15.4)

53,000 (15.5)

72 F (22.2 C) DB

Total

58,100 (17.0)

59,400 (17.4)

57,200 (16.8)

58,600 (17.2)

50% RH

Sensible

51,500 (15.1)

52,100 (15.3)

51,300 (15.0)

51,900 (15.2)

WATER COOLED

GLYCOL COOLED

CHILLED WATER

WATER COOLED

GLYCOL COOLED

CHILLED WATER

5 Tons

5 Tons

5 Tons

5 Tons

5 Tons

5 Tons

Evaporator

MMD60E

MMD60E

MMD92C

MMD59E

MMD59E

MMD91C

Condensing Unit

MCD69W

MCD69W

MCD68W

MCD68W

Net Capacity Data*-BTUH (kW)
80 F (26.7 C) DB

Total

70,800 (20.7)

63,400 (18.6)

94,000 (27.5)

70,000 (20.5)

62,000 (18.2)

94,000 (27.5)

50% RH

Sensible

56,900 (16.7)

54,200 (15.9)

64,000 (18.8)

56,600 (16.6)

53,700 (15.7)

64,000 (18.8)

75 F (23.9 C) DB

Total

66,100 (19.4)

59,300 (17.4)

62,900 (18.4)

65,100 (19.1)

57,900 (17.0)

62,900 (18.4)

50% RH

Sensible

55,200 (16.2)

52,500 (15.4)

53,300 (15.6)

54,800 (16.1)

51,900 (15.2)

53,300 (15.6)

72 F (22.2 C) DB

Total

63,300 (18.5)

57,000 (16.7)

51,300 (15.0)

62,200 (18.2)

55,700 (16.3)

51,300 (15.0)

50% RH

Sensible

54,100 (15.9)

51,400 (15.1)

48,300 (14.2)

53,600 (15.7)

50,900 (14.9)

48,300 (14.2)

60 Hz

50 Hz

AIR COOLED SYSTEM

w/Outdoor Condensing Unit

w/Centrifugal Condensing Unit

w/Outdoor Condensing Unit

w/Centrifugal Condensing Unit

8 Tons

8 Tons

8 Tons

8 Tons

Evaporator

MMD96E

MMD96E

MMD95E

MMD95E

Condensing Unit

PFH096A

MCD96A

PFH095A

MCD95A

Net Capacity Data*-BTUH (kW)
80 F (26.7 C) DB

Total

100,200 (29.4)

95,900 (28.1)

96,700 (28.3)

93,800 (27.5)

50% RH

Sensible

80,500 (23.6)

79,400 (23.3)

79,300 (23.2)

78,300 (22.9)

75 F (23.9 C) DB

Total

93,100 (27.3)

89,500 (26.2)

90,200 (26.4)

87,400 (25.6)

50% RH

Sensible

78,600 (23.0)

77,000 (22.6)

77,400 (22.7)

76,200 (22.3)

72 F (22.2 C) DB

Total

89,200 (26.1)

86,800 (25.4)

86,200 (25.3)

83,600 (24.5)

50% RH

Sensible

77,200 (22.6)

76,500 (22.4)

75,900 (22.2)

74,900 (21.9)

WATER COOLED

GLYCOL COOLED

CHILLED WATER

WATER COOLED

GLYCOL COOLED

CHILLED WATER

8 Tons

8 Tons

8 Tons

8 Tons

8 Tons

8 Tons

Evaporator

MMD96E

MMD96E

MMD8TC

MMD95E

MMD95E

MMD8TC

Condensing Unit

MCD98W

MCD98W

MCD97W

MCD97W

Net Capacity Data*-BTUH (kW)
80 F (26.7 C) DB

Total

105,000 (30.8)

93,000 (27.2)

145,600 (42.7)

101,100 (29.6)

89,600 (26.3)

145,600 (42.7)

50% RH

Sensible

83,300 (24.4)

77,500 (22.7)

98,300 (28.8)

81,000 (23.7)

76,500 (22.4)

98,300 (28.8)

75 F (23.9 C) DB

Total

97,400 (28.5)

86,400 (25.3)

96,900 (28.4)

93,600 (27.4)

84,500 (24.8)

96,900 (28.4)

50% RH

Sensible

81,300 (23.8)

75,000 (22.0)

81,400 (23.8)

78,700 (23.1)

75,600 (22.2)

81,400 (23.8)

72 F (22.2 C) DB

Total

93,200 (27.3)

84,100 (24.6)

80,200 (23.5)

89,400 (26.2)

81,100 (23.8)

80,200 (23.5)

50% RH

Sensible

79,000 (23.1)

75,300 (22.1)

74,300 (21.8)

77,100 (22.6)

73,900 (21.7)

74,300 (21.8)

11

11

Specifications

5 And 8 Ton Split Systems

*The net capacity data has fan motor heat factored in for all ratings and the entering air condition of 72˚F (22.2˚C), 50% RH is the standard rating condition of ASHRAE 127-2001