UNIVERSAL ROOF SUPPORT INSTALLATION

This support has three possible uses:

1. For ASHT+ and S-2100+ chimneys, it must be used on a roof to support the chimney.

2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the

offset.

3. It may be used on a floor, ceiling or roof as a supplementary support when the chimney height

exceeds 15 feet (4.6 m.).

Table 7 gives maximum height of supported chimney.

NOTE: For the AC chimney, a support section (AC8SL) must be used every 40’ (12 m) instead

of the ST.

For roof support installation, refer to the instructions provided with the support.

UNIVERSAL OFFSET SUPPORT INSTALLATION

This support is used to support the chimney above an offset. When the chimney offset is used

to traverse a wall, this support may be used on the wall to support the chimney. The maximum

heights are given in Table 7. For offset support installation, refer to the instructions provided

with the support.

Figure 23

CHIMNEY CHASE AND MULTIPLE

TERMINATIONS

For the purpose of this manual, a chimney chase

is considered a part of the chimney system

rather than part of a building. The termination

must be placed a minimum of 18" (460mm)

above the chase.

For installation where more than one chimney

is located in the same chase or within the same

general area, we suggest that their termina-

tions be separated by at least 16" (410mm)

horizontally and 18" (460mm) vertically. This

separation is to prevent smoke migrating from

one chimney to another (see Figure 23).

18" (460mm)

16"

(410mm)

16"

(410mm)

18" (460mm)

18" (460mm)

Chimney Model

Maximum Height Of Supported Chimney

o

ffset

s

upport

r

oof

s

upport

ASHT+ 8" I.D.

20 feet (6.10 m)

24 feet (7.32 m)

S-2100+ 8" I.D.

14 feet (4.30 m)

16 feet (4.87 m)

AC 8" I.D.

40 feet (12.19 m)

50 feet (15.20 m)

Table 7