Floor Protection

FLOOR PROTECTION

I

M

F

F

T

Floor

Protection

G

G

K

48”

Max.

Depth

Diagram C: Top View

Corner Clearance, Stove and Flue to Wall

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

6” Ø Flue Collar

PIPE

INSTALLATION

A

B (1)

C

D (1)

E†

F (1,4)

Single Wall

Residential

USA-16”

CAN-48mm

1-/4”

49mm

USA-4”

CAN-65mm

14-1/”

68mm

8”

00mm

9”

9mm

Single w/ Pipe

Shield

Residential

USA-10”

CAN-0mm

7-/4”

197mm

USA-4”

CAN-65mm

14-1/”

68mm

8”

00mm

9”

9mm

Double Wall

Residential or

Mobile Home*

USA-10”

CAN-0mm

7-/4”

197mm

USA-18”

CAN-48mm

8-1/”

16mm

8”

00mm

6”

15mm

Double Wall

Alcove

USA-10”

CAN-0mm

7-/4”

197mm

USA-1”

CAN-559mm

8-1/”

16mm

8”

00mm

6”

15mm

PIPE

INSTALLATION

G (4)

H ()

I (6)

J ()

K

L (5)

Single Wall

Residential or Alcove

USA-18”

CAN-5mm

USA-7-/4”

CAN-11mm

USA-51”

CAN-14mm

USA-4-/4”

CAN-1048mm

USA-16”

CAN-450mm

USA 0"

CAN-00mm

Single w/ Pipe

Shield

Residential or Alcove

USA-18”

CAN-5mm

USA-7-/4”

CAN-11mm

USA-45”

CAN-170mm

USA-4-/4”

CAN-1048mm

USA-16”

CAN-450mm

USA 0"

CAN-00mm

Double Wall

Air-Cooled

Residential or Alcove

or Mobile Home*

USA-15”

CAN-450mm

USA-7-/4”

CAN-11mm

USA-45”

CAN-170mm

USA-4-/4”

CAN-1048mm

USA-16”

CAN-450mm

USA 0"

CAN-00mm

Double Wall

Alcove

N/A

USA-7-/4”

CAN-11mm

USA-45”

CAN-170mm

USA-4-/4”

CAN-1048mm

USA-16”

CAN-450mm

USA 0"

CAN-00mm

Installation Clearances - Refer to Diagrams A, B and C

Footnotes:

1- These dimensions to the stove body are

for reference only. Actual distances should

be measured from the stove’s flue collar.

2- Minimum noncombustible hearth pad

dimensions.

3- Shield shall be attached to the rear of the

stove pipe with a 1” air space and must run

from the top of the stove to the ceiling.

4- Not applicable to alcove installations.

5- In corner applications, when installed

at minimum back wall clearances, the

required floor protection is dimensioned

off the back plane of the stove, therefore

the floor protection required off the back

corners (at a 45 degree angle) only needs

to extend to the wall. This situation will

only occur in CANADA installations.

6- Reference dimension only, to assist in

planning the installation.

Clearances to connector pipe shall be mea-

sured from the flue collar of the stove.

† USA=8" (00mm) from door opening, Canada=8"

(00mm) from sides and back of unit

u

Dimensions to Stove Body

* Mobile Home - USA only

Diagram A: Top View-Parallel Installation

Diagram B: Side View-

Alcove and Parallel

Installations

PIPE

INSTALLATION

M

T (6)

Single Wall

Residential or Alcove

84”

14mm

USA-61-/4”

CAN-1619mm

Single w/ Pipe

Shield

Residential or Alcove

84”

14mm

USA-61-/4”

CAN-1619mm

Double Wall

Air-Cooled

Residential or Alcove

or Mobile Home*

7”

189mm

USA-57-1/”

CAN-177mm

Double Wall

Alcove

7”

189mm

USA-57-1/”

CAN-177mm

Advertising