12

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

INSTALLATION ACCESSORIES

The following accessory items are available for
use in the installation of this appliance.

Figure 24

COLD CLIMATE INSULATION

If you live in a cold climate, seal all cracks
around your appliance with noncombustible
material and wherever cold air could enter the
room. It is especially important to insulate
outside chase cavity between studs and under
floor on which appliance rests, if floor is above
ground level.

60"

(1524 mm)

Min. to
Ceiling

12" Min.

(305 mm)

0" Clearance

to Combustible

Side Wall

Max. Projection 12" (305 mm)

Combustible

Mantel

Figure 23

FINISHING REQUIREMENTS
Wall Details and Combustible Mantels

Complete finished interior wall. To install the
appliance facing flush with the finished wall,
position framework to accommodate the thick-
ness of the finished wall

(Figure 23 ). Both

Figures 23 and 24 show a combustible mantel
shelf projecting a maximum of 12" (305 mm)
from the wall, and which must be installed a
minimum distance of 12" (305mm) from the
top of the firebox opening. No other mantel
length/height combinations are allowable for
this fireplace.

A hearth extension is not required with this
appliance. Any hearth extension used is for
appearance only and does not have to conform
to standard hearth extension installation re-
quirements.

Note: Combustible wall finish materials and/or
surround materials must not be allowed to
encroach the area defined by the appliance
front face (black sheet metal). Never allow
combustible materials to be positioned in front
of or overlapping the appliance front face.

Elbow

10" X 45 Degree

10KE45

Firestop

BV 10"

10KBF

12" Length

10KL1

24" Length

10KL2

36" Length

10KL3

Security 10" B-vent

Adjustable Length

10KAL

Brace Support

BV 10"

10KBS

Fireplace Opening

Typical Installation

10"

Min.

12"

Min.

18"

12"

Max.

Combustible
Mantel and Trim
(See Note)

3 Sheet Metal Screws
#10 x 3/4" Max. Flat Head

5"

Top Of Fireplace

Non

Combustible

Material

Sheet Metal

Spacer

Finished Wall

Header

Note: Mantel At Minimum Height Should Be Affixed to Framing Hinge Posts At Right
And Left Of The Fireplace. Do Not Use Molly Bolts In Front Of The Fireplace.

18 5/8"

Non-Combustible Material

1-3/8"

11-3/8"

Min.

Advertising
This manual is related to the following products: