NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Venting

Gas Vent Rule – Gas vent caps are not permit-
ted within 8 feet (2.4 mm) of a vertical wall or
similar obstruction. Gas vent caps that are
located 8' or more from a portion of a building
which extends at an angle greater than 45

°

upward from the horizontal may terminate in
accordance with

Table 1 (Figure 3), provided

that in no case shall any discharge opening on
the cap be less than 2' (610 mm) horizontally
from the roof surface (National Fuel Gas Code
ANSI Z223.1 (NFPA 54) 7.6.2) (CAN/CGA B149).

CLEARANCES

Minimum clearance to combustibles for the ap-
pliance is as follows: sides and back - 3/8" (9.52
mm), floor - 0" (0 mm), adjacent wall - 0" (0 mm),
ceiling - 37-1/2" (953 mm).

APPLIANCE SPECIFICATIONS

Figure 2

Table 1

Note: Venting terminals shall not be recessed
into a wall or siding.

Flat to 6/12

1' 0"

0.3

Over 7/12 to 9/12

2' 0"

0.6

Over 10/12 to 12/12

4' 0"

1.2

Over 13/12 to 16/12

6' 0"

1.8

Over 17/12 to 21/12

8' 0"

2.4

Roof Slope

Minimum Height

from Roof to Lowest

Discharge Opening

Feet

Meters

Roof Pitch is X/12

12

X

Minimum Height from Roof
to Lowest Discharge Opening

The appliance should be mounted on a fully
supported base extending the full width and
depth of the unit. The appliance may be located
on or near conventional construction materi-
als. However, if installed on combustible mate-
rials, such as carpeting, vinyl tile, etc., a metal
or wood barrier covering the entire bottom
surface must be used.

These appliances may be used for bedroom
installations in the United States and are listed
accordingly. These units may not be installed
in bedrooms in Canada.

Figure 3

Front View

12-15/32

28-15/32

41-5/16

47-9/32

52-11/32

LSBV-36: 41-3/4
LSBV-42: 47-3/4

7-3/32

5-3/4

LSBV-36: 37
LSBV-42: 43

Left Side View

1-7/16

8-7/8

Right Side View

7-7/16

15-27/32

1-25/32

4-13/32

16-1/16

2-9/32

Top View

LSBV-36: 23-1/2
LSBV-42: 29-1/2

20-1/32

8-15/32

19/32

Gas Line
Or Switch
Wire Outlet

Gas Line
Or Switch
Wire Outlet

Combustion

Air Inlet

Junction
Box
Location