Langley/Empire DV-40E-5 User Manual

Page 10

Advertising
background image

Page 10

19562-1-0606

Installing Wall Bracket (Figures 5 and 6)

After finding a location for the furnace, gas supply and vent, the

wall bracket must be positioned and installed. The bracket should

be mounted to the wall studs, if possible, or anchored solidly to the

wall. Use the (2) 10 x 1" (25mm) hex-head screws or (2) plastic

anchors provided. Drill (2) 5/16" (8mm) diameter holes in wall if

plastic anchors are used. Attach the two wall mounting brackets

to the casing back by using (4) 10 x 1/2" (13mm) hex-head screws

provided.

Figure 5

WALL

CASING

BACK

#10 X 1"

WALL MOUNTING BRACKET

WALL

BRACKET

#10 X 1/2"

#10 X 1/2"

4" (102mm)

Figure 6

WALL

INTAKE FLEX HOSE

WITH CLAMPS

EXHAUST

INTAKE AIR

MOUNTING PLATE

EXHAUST ELBOW MAY

BE CUT TO LENGTH

TO FIT VENT BOX.

SECURE IN PLACE

USING HOSE CLAMPS

PROVIDED.

KEEP CAP ON

UN-USED AIR

INTAKE OPENING

Figure 7

EXHAUST AIR

ORANGE SILICONE

ELBOW CONNECTOR

INTAKE AIR

BLACK FLEXIBLE HOSE

Figure 8

Figure 9

Venting (Figures 7, 8 and 9)

This unit is vented directly out the back using the concentric vent

tube assembly provided. See Figure 2 for vent hole location. This

hole location can be conveniently moved closer to unit exhaust

outlet tube to avoid wall stud interference if necessary. The orange

silicone exhaust elbow would need to be cut to length. Do not

locate vent directly behind the exhaust outlet. Do not use the orange

silicone elbow for extended vent runs where the possibility of

flue condensate exists unless the run is horizontal and the elbow is

sloped downward away from the heater. See Figure 12 for extended

vertical venting.
The vent provided will accommodate walls up to 10" thick and

can be cut shorter for thinner walls if desired by using a hacksaw

or cut-off saw. Be sure to leave the minimum 3/4" of tube length

extending beyond the outside wall plate. Both the inner and outer

tube will be cut to the same length as the inner exhaust tube has an

extension piece which is added during final outside assembly.

VENT TUBING

SILICONE COUPLING

HOSE CLAMP

HOSE CLAMP

EDGE

EXHAUST CONNECTIONS

INTAKE FLEX HOSE CONNECTION

WITH INTERNAL METAL COUPLING

VENT COUPLING CONNECTIONS

EXTENDED VENT