Linksys SPA9x2 Phone Administration Guide

68

Distinctive Ring Patterns

Setting Regional Parameters

Distinctive Ring Patterns

Ring cadence defines the ringing pattern that announces a telephone call.

Ring Pattern Notes

The default cadence script for eight ring patterns is shown in the figure above.

Control Timer Values (sec)

Control Timer Value Notes

The following table describes all control timer parameters. Each value is displayed in seconds.

Field

Description

Reorder Delay

Delay after far end hangs up before reorder tone is played. 0 = plays
immediately, inf = never plays. Range: 0–255 seconds.

Defaults to 255.

Call Back Expires

Expiration time in seconds of a call back activation. Range: 0–65535
seconds.

Defaults to 1800.

Call Back Retry Intvl

Call back retry interval in seconds. Range: 0–255 seconds.

Defaults to 30.

Advertising