12 stove installation – Lopi Leyden 028-S-75-2 User Manual

Page 12

Advertising
background image

12

Stove Installation

(for qualified installers only)

© Travis Industries

100-01177

4060802

Chimney Requirements

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

UL 103 HT Chimney must be used from the first ceiling or floor penetration to the chimney cap.

Use 6" diameter type UL 103 HT chimney from one manufacturer (do not mix brands) or code
approved masonry chimney with a flue liner.

Chimney must be fastened to each adjoining section.

Follow the chimney manufacturer's clearances and requirements.

Use the chimney manufacturer's fire stops, attic guards, roof supports, and flashings when passing
through a ceiling

No more than 180

o

of elbows (two 90

o

elbows, or two 45

o

& one 90

o

elbow, etc.) may be used for the

entire system (connector and chimney).

NOTE: Additional elbows may be allowed if draft is sufficient. Whenever elbows are used the draft is
adversely affected. Additional chimney height may be required to boost draft.

Chimney Cap

(See the section "Chimney

Termination Requirements"

for more details)

Factory Built

Chimney Sections

Minimum Air Space to

Combustibles (See

Chimney Manufacturer's

Instructions - usually 2")

Floor Penetration Equipment

(Attic Radiation Shield with

Chimney Support)

Roof Penetration Equipment

(Roof Radiation Shield,

Flashing, Storm Collar)

}

}

Floor

Protection

Connector Clearance

(as outlined in this manual)

}

Minimum System 15'

Maximum System 33'

Connector

On singlewall pipe

the crimped end

points downward.

Figure 7

Drafting
Performance

This appliance relies upon natural draft to operate. External forces, such as wind,
barometric pressure, topography, or factors of the home (negative pressure from exhaust
fans, chimneys, air infiltration, etc.), may adversely affect draft. Travis Industries can not be
responsible for external forces leading to less than optimal performance.