Troubleshooting, Connection of the la36 with the cs16, Action – Linak TECHLINE LA36 User Manual

Page 15: Possible cause, Symptom

Advertising
background image

15

Troubleshooting

Action

• Connect the actuator to the
power

supply

• Change cable
• Send actuator for repair

• Align or reduce load
• Send actuator for repair

• Send actuator for repair

• Send actuator for repair

• Change cable
• Send actuator for repair

• Increase power supply
• Thicker cable

• Reduce load

Possible cause

• The actuator is not connected

to the power supply

• Cable damaged

• Misalignment or overload in

application

• Gearwheel or spindle
damaged

• Clutch is worn
• Motor is damaged

• Cable damaged
• Potentiometer damaged

• Insufficient power supply
• Voltage drop in cable

• Load is higher than specified

Symptom

No motor sound or
movement of piston rod

Excessive electricity
consumption

Motor runs but spindle
does not move

Actuator cannot lift full
load

No signal from
potentiometer or hall
effect sensor

Motor runs too slowly or
does not give full force

Actuator cannot hold the
chosen load

1 2 3 4 5 6 7 8 9 10 11 12

CS16-4-24

MAX MIN

P

HB40 serie

-

+

R = RED . O = ORANGE . GR = GREEN

R GR O

Connection of the LA36 with the CS16

Advertising