OPTIONAL ACCESSORIES − MUST BE ORDERED EXTRA

B" Width Models

C" Width Models

D" Width Models

FILTER KITS

1

Air Filter and

Rack Kit

Horizontal (end)

Size of filter − in.

(mm)

87L96 − 18 x 25 x 1

(457 x 635 x 25)

87L97 − 20 x 25 x 1

(508 x 635 x 25)

87L98 − 25 x 25 x 1

(635 x 635 x 25)

Side Return

Single

44J22

44J22

44J22

Ten Pack

66K63

66K63

66K63

Size of filter − in. (mm)

16 x 25 x 1

(406 x 635 x 25)

16 x 25 x 1

(406 x 635 x 25)

16 x 25 x 1

(406 x 635 x 25)

EZ Filter Base

Catalog No. − Ship. Wt. − lbs. (kg)

73P56 − 7 (3)

73P57 − 8 (4)

73P58 − 10 (5)

Size of field provided filter − in.

(mm)

16 x 25 x 1

(406 x 635 x 25)

20 x 25 x 1

(508 x 635 x 25)

24 x 24 x 1

(610 x 610 x 25)

CABINET ACCESSORIES

Down−Flow Additive Base

11M60

11M61

11M62

Horizontal Support Frame Kit

56J18

56J18

56J18

Return Air Base

76M88

74M74

74M75

CONDENSATE DRAIN KITS

Condensate Drain Heat Cable

6 ft. (1.8 m)

26K68

26K68

26K68

24 ft. (7.3 m)

26K69

26K69

26K69

50 ft. (15.2 m)

26K70

26K70

26K70

Heat Cable Tape

Fiberglass − 1/2 in. x 66 ft.

39G04

39G04

39G04

p

Aluminum foil − 2 in. x 60 ft.

39G03

39G03

39G03

Condensate Trap Alternate Location Kit − Up−Flow Only

76M20

76M20

76M20

CONTROLS

Twinning Kit

15L38

15L38

15L38

TERMINATION KITS − See Installation Instructions for specific venting information.

4

Termination

Kit

Concentric

1−1/2 in. (38 mm)

71M80

− − −

− − −

Kits
Direct Vent

2 in. (51 mm)

− − −

69M29

− − −

Direct Vent
Applications

3 in. (76 mm)

− − −

60L46

60L46

Applications
Only

Wall − Close
C

l

2 in. (51 mm)

22G44

− − −

− − −

Couple

3 in. (76 mm)

44J40

44J40

44J40

Close Couple WTK − 2 in. (51 mm)

30G28

− − −

− − −

3 in. (76 mm)

81J20

81J20

81J20

2, 4

Termination

Kit

Di

t

Roof

2 in. (51 mm)

15F75

15F75

− − −

Kits − Direct or
Non−Direct Vent

Wall − Wall Ring
Kit

2 in (51 mm)

15F74

15F74

3

15F74

4

Roof Termination Flashing Kit − Direct or Non−Direct

Vent − Contains two flashings.

44J41

44J41

44J41

1

Cleanable polyurethane frame type filter.

2

Kits contain enough parts for two, non−direct vent installations.

3

Non−direct vent only.

GAS HEAT ACCESSORIES

Input

1

High Altitude

Orifice Kit

Natural Gas Only

High Altitude Pressure

Switch Kit

LPG/Propane Kit

Input

Natural Gas Only

4501−7500 ft.

(1372−2286 m)

7501−10,000 ft.

(2286−3048 m)

0−7500 ft.

(0−2286 m)

7501−10,000 ft.

(2286−3048 m)

−045

59M16

− − −

95M22

83M74

83M75

−070

59M16

56M05

56M06

83M74

83M75

−090

59M16

75M20

56M07

83M74

83M75

−110

59M16

75M20

56M07

83M74

83M75

−135

59M16

56M04

60M35

83M74

83M75

1

Required for proper operation at altitudes from 7501 to 10,000 ft. (2286 to 3048 m).