Exhaust pipe venting, Termination kits – Lennox Hearth G43UF User Manual

Page 7

Advertising
background image

G43UF / Page 7

EXHAUST PIPE VENTING TABLE

1

Maximum Equivalent Vent Length − One or Two Pipe Applications

Altitude

Vent Size

(diameter)

G43UF−24B−045

G43UF−24B−070
G43UF−36B−070

G43UF−36C−090
G43UF−48C−090

2

G43UF−48C−110

2

G43UF−60C−110

3

G43UF−60D−135

(

)

ft.

m

ft.

m

ft.

m

ft.

m

ft.

m

0 − 2000 ft.

(0 609

)

2 in.

110

34

70

21

50

15

30

9

n/a

n/a

(0 − 609 m)

2−1/2 in.

135

41

135

41

100

31

70

21

n/a

n/a

3 in.

160

49

160

49

125

38

125

38

4

125

4

38

4 in.

250

76

250

76

225

69

200

61

180

55

2001 − 4500 ft.

(610 1371

)

2 in.

110

34

70

21

50

15

20

6

n/a

n/a

(610 − 1371 m)

2−1/2 in.

135

41

135

41

100

31

70

21

n/a

n/a

3 in.

160

49

160

49

125

38

125

38

4

90

4

27

4 in.

250

76

250

76

225

69

200

61

180

55

4501 − 7500 ft.

(1372 2286

)

2 in.

110

34

70

21

30

9

n/a

n/a

n/a

n/a

(1372 − 2286 m)

2−1/2 in.

135

41

135

41

100

31

70

21

n/a

n/a

3 in.

160

49

160

49

125

38

125

38

4

90

4

27

4 in.

250

76

250

76

225

69

200

61

180

55

7501 − 10,000 ft.

(2287 3048

)

2 in.

110

34

70

21

n/a

n/a

n/a

n/a

n/a

n/a

,

(2287 − 3048 m)

2−1/2 in.

135

41

135

41

100

31

70

21

n/a

n/a

3 in.

160

49

160

49

125

38

125

38

4

90

4

27

4 in.

250

76

250

76

225

69

200

61

180

55

NOTE − Minimum Equivalent Vent Pipe length is 15 feet (4.6 m).

1

Maximum Equivalent Vent Length" permitted is defined as Total Length (linear feet) of vent pipe, plus equivalent length (ft.) of fittings, plus equivalent length (ft.) of termination".

2

110 models must have the supplied 90° street ell installed directly into the unit flue collar. The street ell must be included in the elbow count.

3

135 models must have 3 in. to 2 in. reducing elbow (supplied) installed directly into the flue collar. Reducing ell must be included in elbow count.

4

90

_ elbows must be limited to 3 in. sweep type elbows.

VENTING NOTES Ċ One 90

_elbow is equivalent to 5 feet (1.5 m) of straight vent pipe.

Two 45

_ elbows are equal to one 90_ elbow.

One 45

_ elbow is equivalent to 2.5 feet (.75 m) of straight vent pipe.

Wall and roof termination (non−concentric) exhaust pipe must terminate with reducer to improve exhaust velocity away from intake piping.

045 and 070 − 2, 2−1/2, 3 or 4 in. − terminate with 1−1/2 in. pipe
090 − 2, 2−1/2, 3 or 4 in. − terminate with 2 in. pipe
110 − 2, 2−1/2, 3 or 4 in. − terminate with 2 in. pipe
135 − 3 or 4 in. − terminate with 2 in. pipe

TERMINATION KITS − EQUIVALENT VENT LENGTHS

Vent Pipe Equivalent Length − ft. (m)

Heat

Vent Pipe

Diameter

Concentric

Kits

Close Couple

Kits

Wall Ring

Kit

Outdoor Exhaust

Accelerator

(Diameter X Length)

Heat

Size

1−1/2 in.

(38 mm)

2 in.

(51 mm)

3 in.

(76 mm)

2 in.

(51 mm)

3 in.

(76 mm)

2 in.

(51 mm)

1−1/2 x 12 in.

(38 x 305 mm)

2 x 12 in.

(51 x 305 mm)

in.

mm

71M80

69M29

60L46

22G44

30G28 (WTK)

44J40

81J20 (WTK)

15F74

− − −

− − −

2

51

12 (3.6)

not allowed not allowed

4 (1.2)

1

4 (1.2)

4 (1.2)

4 (1.2)

not allowed

045

2−1/2

64

15 (4.6)

not allowed not allowed

5 (1.5)

1

5 (1.5)

5 (1.5)

5 (1.5)

not allowed

−045

3

76

21 (6.4)

not allowed not allowed

7 (2.1)

1

7 (2.1)

7 (2.1)

7 (2.1)

not allowed

4

102

42 (12.8)

not allowed not allowed

14 (4.3)

1

14 (4.3)

14 (4.3)

14 (4.3)

not allowed

2

51

12 (3.6)

not allowed not allowed

4 (1.2)

1

4 (1.2)

4 (1.2)

4 (1.2)

not allowed

070

2−1/2

64

15 (4.6)

not allowed not allowed

5 (1.5)

1

5 (1.5)

5 (1.5)

5 (1.5)

not allowed

−070

3

76

24 (7.3)

not allowed not allowed

8 (2.4)

1

8 (2.4)

8 (2.4)

8 (2.4)

not allowed

4

102

42 (12.8)

not allowed not allowed

14 (4.3)

1

14 (4.3)

14 (4.3)

14 (4.3)

not allowed

2

51

not allowed

3 (1)

3 (1)

not allowed

1 (0.3)

2

1 (0.3)

not allowed

1 (0.3)

090

2−1/2

64

not allowed

6 (1.8)

6 (1.8)

not allowed

2 (0.6)

2

2 (0.6)

not allowed

2 (0.6)

−090

3

76

not allowed

6 (1.8)

6 (1.8)

not allowed

2 (0.6)

2

2 (0.6)

not allowed

2 (0.6)

4

102

not allowed

12 (3.7)

12 (3.7)

not allowed

4 (1.2)

2

4 (1.2)

not allowed

4 (1.2)

2

51

not allowed

3 (1)

3 (1)

not allowed

1 (0.3)

2

1 (0.3)

not allowed

1 (0.3)

110

2−1/2

64

not allowed

6 (1.8)

6 (1.8)

not allowed

2 (0.6)

3

2 (0.6)

not allowed

2 (0.6)

−110

3

76

not allowed

6 (1.8)

6 (1.8)

not allowed

2 (0.6)

3

2 (0.6)

not allowed

2 (0.6)

4

102

not allowed

12 (3.7)

12 (3.7)

not allowed

4 (1.2)

3

4 (1.2)

not allowed

4 (1.2)

135

3

76

not allowed not allowed

15 (4.6)

not allowed

6 (1.8)

3

6 (1.8)

not allowed

6 (1.8)

−135

4

102

not allowed not allowed

25 (7.6)

not allowed

10 (3.0)

3

10 (3.0)

not allowed

10 (3.0)

1

Requires field provided 1−1/2 in. (38 mm) outdoor exhaust accelerator.

2

Requires field provided 2 in. (51 mm) outdoor exhaust accelerator.

3

For use only in non−direct vent applications, when snow riser is not required. Requires field provided 2 in. (51 mm) outdoor exhaust accelerator.