EVENT LOG

Displays any event codes that may

have been detected by the software.

For more information, refer to Event

Log.

Event Log

The event log holds a maximum of 30 events. After the log

reaches 30 events, older events are erased to make room for

newer ones.
Each event log entry contains the following information:

Event number

Odometer value when the event occurred

Hour meter value at the time the event occurred

Current drawn by the motor when the event occurred

(treadmill only)

The following table contains a list of events detectable by the

software.

Table 5. Event log numbers and descriptions

Event

Number

Description of Event

00

Upper PCA memory location event

02

RAM location event

03

EEPROM checksum event

05

Depressed key at power up

09

Lower PCA memory test event

10

Line Frequency out of acceptable range

11

Watchdog (Upper PCA) low voltage power

12

Watchdog (Lower PCA) low voltage power

13

Fan at incorrect speed (version 1 treadmills)

14

Fan fail (Lower PCA)

15

AC input voltage too high

16

AC input voltage too low

20

Too many maximum power requests in one second

21

Too many maximum consecutive power requests

22

No motor pulses at start up

Advertising