Standards Compliance for SNMP Traps
D-2
7112-A2-GB20-10
March 1998
SNMP Trap
Description
Possible Cause
authenticationFailure
Failed attempts to access
the unit.
There are no
variable-bindings.
H
SNMP message not properly
authenticated.
H
Three unsuccessful attempts
were made to enter a correct
login/password combination.
H
IP address security is
enabled, and a message was
received from SNMP manager
whose address was not on the
list of approved managers.
H
Attempt to set a read-only MIB
object.
Traps: linkUp and linkDown
The link SNMP traps are:
H
linkUp – The unit recognizes that one of the failed communication interfaces
is operational (up).
H
linkDown – The unit recognizes a failure in one of the communication
interfaces.