IMS-4000 Manual

34

Battery Replacement

The IMS-4000 Node uses one (1) 6V 3.4AH rechargeable battery (included) for backup power in
the event that main power fails. The unit will constantly recharge the battery whenever the power
switch is turned on and the unit is plugged into a power supply.
In the event you need to replace the battery, be sure to use battery part # BAT-0006 (see Appendix
C: Accessories) to ensure compatibility.
To install the new battery, first slide the power switch to the OFF position and disconnect the power
adapter. Next, remove the top cover of the unit by removing the six screws using a small flat-head
screwdriver. Remove the wire connectors from the old battery and replace it with the new one.
Reconnect the wires to the new battery and reattach the top cover.

Note: Earlier versions of the Node used six (6) C-size 2000mAhr ni-cad batteries. If you have
one of these you must use C-size ni-cads to replace them.

Figure 8: Battery replacement in the Node unit

Rack Mount Installation

The IMS-4000 Node can be rack mounted using the included rack mount brackets. Follow the
steps below:

1) Attach rack-mount brackets to the Node with a Phillips screwdriver.
2) Attach the unit to the equipment rack using two pan-head screws per side. Tighten the

screws with a Phillips screwdriver.

3) Plug the power adapter into a power outlet.